MSP430F663x
www.ti.com
SLAS566C –JUNE 2010–REVISED AUGUST 2012
Schmitt-Trigger Inputs – General Purpose I/O(1) (continued)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
1.8 V
3 V
MIN
0.45
0.75
0.3
TYP
MAX UNIT
1.00
V
VIT–
Negative-going input threshold voltage
1.65
1.8 V
3 V
0.8
V
Vhys
Input voltage hysteresis (VIT+ – VIT–)
0.4
1.0
For pullup: VIN = VSS
For pulldown: VIN = VCC
RPull
CI
Pullup or pulldown resistor
Input capacitance
20
35
5
50
kΩ
VIN = VSS or VCC
pF
Inputs – Ports P1, P2, P3, and P4(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
MIN
MAX UNIT
Port P1, P2, P3, P4: P1.x to P4.x,
External trigger pulse duration to set interrupt flag
t(int)
External interrupt timing(2)
2.2 V, 3 V
20
ns
(1) Some devices may contain additional ports with interrupts. See the block diagram and terminal function descriptions.
(2) An external signal sets the interrupt flag every time the minimum interrupt pulse duration t(int) is met. It may be set by trigger signals
shorter than t(int)
.
Leakage Current – General Purpose I/O
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
MIN
MAX UNIT
±50 nA
(1)(2)
Ilkg(Px.x)
High-impedance leakage current
1.8 V, 3 V
(1) The leakage current is measured with VSS or VCC applied to the corresponding pin(s), unless otherwise noted.
(2) The leakage of the digital port pins is measured individually. The port pin is selected for input and the pullup or pulldown resistor is
disabled.
Outputs – General Purpose I/O (Full Drive Strength)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
I(OHmax) = –3 mA(1)
VCC
MIN
VCC – 0.25
VCC – 0.60
VCC – 0.25
VCC – 0.60
MAX UNIT
VCC
1.8 V
I(OHmax) = –10 mA(2)
I(OHmax) = –5 mA(1)
I(OHmax) = –15 mA(2)
I(OLmax) = 3 mA(1)
I(OLmax) = 10 mA(2)
I(OLmax) = 5 mA(1)
I(OLmax) = 15 mA(2)
VCC
VOH
High-level output voltage
V
VCC
3 V
1.8 V
3 V
VCC
VSS VSS + 0.25
VSS VSS + 0.60
VSS VSS + 0.25
VSS VSS + 0.60
VOL
Low-level output voltage
V
(1) The maximum total current, I(OHmax) and I(OLmax), for all outputs combined should not exceed ±48 mA to hold the maximum voltage drop
specified.
(2) The maximum total current, I(OHmax) and I(OLmax), for all outputs combined should not exceed ±100 mA to hold the maximum voltage
drop specified.
Copyright © 2010–2012, Texas Instruments Incorporated
51