CC1110Fx / CC1111Fx
4
Operating Conditions
4.1 CC1110Fx Operating Conditions
The operating conditions for CC1110Fx are listed in Table 3 below.
Parameter
Min
−40
2.0
Max
85
Unit
C
Condition
Operating ambient temperature, TA
Operating supply voltage (VDD)
3.6
V
All supply pins must have the same voltage
Table 3: Operating Conditions for CC1110Fx
4.2 CC1111Fx Operating Conditions
The operating conditions for CC1111Fx are listed in Table 4 below.
Parameter
Min
0
Max
85
Unit
C
Condition
Operating ambient temperature, TA
Operating supply voltage (VDD)
3.0
3.6
V
All supply pins must have the same voltage
Table 4: Operating Conditions for CC1111Fx
5 General Characteristics
TA = 25 C, VDD = 3.0 V if nothing else stated
Parameter
Min
Typ
Max
Unit
Condition/Note
Radio part
Frequency range
300
391
782
1.2
1.2
26
348
464
928
500
250
500
MHz
MHz
MHz
Data rate
kBaud
kBaud
kBaud
2-FSK (500 kBaud only characterized @ 915
MHz on CC1110Fx)
GFSK, OOK, and ASK
(Shaped) MSK (also known as differential
offset QPSK) 500 kBaud only characterized
@ 915 MHz
Optional Manchester encoding (the data rate
in kbps will be half the baud rate)
Wake-Up Timing
PM1 Active Mode
4
µs
µs
Digital regulator on. HS RCOSC and high
speed crystal oscillator off. 32.768 kHz
XOSC or low power RCOSC running.
SLEEP.OSC_PD=1and CLKCON.OSC=1
PM2/3 Active Mode
100
Digital regulator off. HS RCOSC and high
speed crystal oscillator off. 32.768 kHz
XOSC or low power RCOSC running (PM2).
No crystal oscillators or RC oscillators are
running in PM3
SLEEP.OSC_PD=1and CLKCON.OSC=1
Table 5: General Characteristics
SWRS033H