bq24030, bq24031, bq24032,
bq24032A, bq24035, bq24038, bq24039
www.ti.com
SLUS618C–AUGUST 2004–REVISED JUNE 2005
ELECTRICAL CHARACTERISTICS (continued)
over junction temperature range (0°C ≤ TJ ≤ 125°C) and the recommended supply voltage range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
USB PIN INPUT CURRENT REGULATION
VI(BAT) > V(LOWV)
,
VI(USB) - VI(BAT) > V(DO-MAX), ISET2= Low,
ISET3 = Low, PSEL = Low, or no AC
(bq24039),
(14)
100
USB input current range,
bq24030/1/2/2A/5/8;
bq24039(12)
(13)
I(USB)
mA
VI(BAT) > V(LOWV)
,
VI(USB) - VI(BAT) > V(DO-MAX), ISET2= High,
ISET3 = Low, PSEL = Low, or no AC
(14)
400
500
(12)
(bq24039),
BAT PIN CHARGING VOLTAGE REGULATION, VO (BAT-REG) + V (DO-MAX) < VCC, ITERM < IBAT(OUT) ≤ 1 A
bq24030/2/2A/5/8
4.2
4.36
4.36
4.2
Battery
charge
voltage
bq24031
V
VBXL = HI
VBXL = LO
TA = 25°C
VO(BAT-REG)
bq24038
–0.5%
–1%
0.5%
1%
Battery charge voltage regulation
accuracy
CHARGE TERMINATION DETECTION
Charge termination detection
range
VI(BAT) < V(RCH),
I(TERM) = (K(SET) × V(TERM))/ RSET
I(TERM)
10
235
235
95
150
265
265
130
mA
mV
mV
mV
V(TERM-AC/USB)
bq24032
Charge termination set voltage,
measured on ISET1
VI(BAT) > V(RCH)
250
250
100
V(TERM-AC)
bq24030/1/2A/5/8
AC-charge termination detection
voltage, measured on ISET1
VI(BAT) > V(RCH) , PSEL = High,
ACPG = Low
V(TAPER-USB)
bq24030/1/2A/5/8
USB-charge termination detection VI(BAT) > V(RCH), PSEL = Low or
voltage, measured on ISET1
PSEL = High and ACPG = High
VI(BAT) > V(RCH) , ISET3 = Low
VI(BAT) > V(RCH) , ISET3 = High
95
100
250
130
265
V(TERM-AC/USB)
bq24039 only
AC/USB charge termination detec-
tion voltage, measured on ISET1
mV
ms
235
tFALL = 100 ns, 10 mV overdrive,
ICHG increasing above or decreasing be-
low threshold
Deglitch time for termination de-
tection
TDGL(TERM)
22.5
TEMPERATURE SENSE COMPARATORS
VLTF
VHTF
ITS
High voltage threshold
Temp fault at V(TS) > VLTF
Temp fault at V(TS) < VHTF
2.465
0.485
94
2.500
0.500
100
2.535
0.515
106
V
V
Low voltage threshold
Temperature sense current source
µA
R(TMR) = 50 kΩ, VI(BAT) increasing or
decreasing above and below;
100-ns fall time, 10-mv overdrive
Deglitch time for temperature fault
detection(15)
TDGL(TF)
22.5
ms
BATTERY RECHARGE THRESHOLD
VO(BAT-REG)
–0.075
VO(BAT-REG)
–0.100
VO(BAT-REG)
–0.125
VRCH
Recharge threshold voltage
V
R(TMR) = 50 kΩ, VI(BAT) increasing
or decreasing below threshold,
100-ns fall time, 10-mv overdrive
Deglitch time for recharge detec-
tion(15)
TDGL(RCH)
22.5
ms
(12) With the PSEL= low, the bqTINY-III defaults to USB charging. If USB input is ≤ VBAT, then the bqTINY-III charges from the AC input at
the USB charge rate. In this configuration, the specification is 400 mA (min) and 500 mA (max) for bq24030/2/2A/5/8 only.
(13) With the PSEL= low, the bqTINY-III defaults to USB charging. If USB input is ≤ VBAT, then the bqTINY-III charges from the AC input at
the USB charge rate. In this configuration, the specification is 80 mA (min) and 100 mA (max) for bq24030/1/2A/5/8 only; 75 mA (min)
and 100 mA (max) for bq24032.
(14) ISET3 - bq24039 only; ISET3 = High-increases current range by a factor of 2 (min - max)
(15) All deglitch periods are a function of the timer setting and is modified in DPPM or thermal regulation modes by the percentages that the
program current is reduced.
6