DS_8009R_056  
73S8009R Data Sheet  
OFF is low by  
OFF is low by  
card extracted  
any fault  
PRES  
OFF  
CMDVCC  
VCC  
outside card session  
within card session  
within card  
session  
Figure 7: OFF Activity Outside and Inside a Card Session  
3.8 Power-down Operation  
A power-down function is provided that disables all analog functions. The power-down state is only  
allowed in the de-activated condition. The host invokes the power-down state when it is desirable to save  
power.  
The signals PRES and PRES are functional in the power-down state so that a card insertion asserts OFF  
high. If there is no card present (OFF = low) in power-down mode, the pull-up resistor is disabled so that  
no current is drawn from VDD. If a card is inserted, the pull-up resistor is enabled and OFF goes high.  
Upon receiving the OFF indication, the host must then de-assert power down (PWRDN) and wait until the  
circuit is ready. When PWRDN is de-asserted, OFF goes low to indicate that the circuit is not ready (it is  
going through the power-on recovery time). When the circuit is ready, OFF will go high if the card is  
present. Figure 8 illustrates the behavior of the circuit for PWRDN events.  
OFF will go high if card is present and there are no faults  
PRES  
OFF goes low when PWRDN is de-asserted while circuit starts up  
OFF going high indicates  
OFF  
circuit is ready  
PWRDN while CMDVCCx=0  
has no effect  
PWRDN  
RC OSC  
PWRDN will have effect  
when CMDVCCx=1  
~30 µs  
Controller must wait for OFF=1 after  
setting PWRDN=0 before setting  
CMDVCC(3/5)=0  
~30 µs  
CMDVCC3 /  
CMDVCC5  
RDY - indicates VCC is OK  
Figure 8: Power-down Operation  
Rev. 1.3  
17