 浏览型号71M6521DE-IGTR/F的Datasheet PDF文件第78页浏览型号71M6521DE-IGTR/F的Datasheet PDF文件第79页浏览型号71M6521DE-IGTR/F的Datasheet PDF文件第80页浏览型号71M6521DE-IGTR/F的Datasheet PDF文件第81页浏览型号71M6521DE-IGTR/F的Datasheet PDF文件第83页浏览型号71M6521DE-IGTR/F的Datasheet PDF文件第84页浏览型号71M6521DE-IGTR/F的Datasheet PDF文件第85页浏览型号71M6521DE-IGTR/F的Datasheet PDF文件第86页  
71M6521DE/71M6521FE  
Energy Meter IC  
DATASHEET  
JANUARY 2008  
CECONFIG  
Name  
Default  
Description  
[bit]  
Number of consecutive voltage samples below SAG_THR before a sag  
alarm is declared. The maximum value is 255. SAG_THR is at address  
0x14.  
80  
(0x50)  
[15:8]  
SAG_CNT  
[7]  
[6]  
--  
0
0
Unused  
FREQSEL  
Selected phase for frequency monitor (0 = A, 1 = B).  
When zero, causes the pulse generators to respond to WSUM_X and  
VARSUM_X. Otherwise, the generators respond to values the MPU places  
in APULSEW and APULSER.  
[5]  
EXT_PULSE  
1
[4]  
[3]  
[2]  
--  
0
0
0
Unused  
When 1, the current gain of channel B is increased by 8. The gain factor  
controlled by In_SHUNT is referred to as In_8 throughout this document.  
IB_SHUNT  
IA_SHUNT  
When 1, the current gain of channel A is increased by 8.  
When PULSE_SLOW = 1, the pulse generator input is reduced by a factor of  
64. When PULSE_FAST = 1, the pulse generator input is increased 16x.  
These two parameters control the pulse gain factor X (see table below).  
Allowed values are either 1 or 0. Default is 0 (X = 6).  
[1]  
[0]  
PULSE_FAST  
PULSE_SLOW  
0
0
X
PULSE_SLOW  
PULSE_FAST  
1.5 * 22 = 6  
1.5 * 26 = 96  
1.5 * 2-4 = 0.09375  
1.5  
0
0
1
1
0
1
0
1
CE TRANSFER VARIABLES  
When the MPU receives the XFER_BUSY interrupt, it knows that fresh data is available in the transfer variables. The transfer  
variables can be categorized as:  
1.  
2.  
3.  
4.  
5.  
6.  
Fundamental energy measurement variables  
Instantaneous (RMS) values  
Other measurement parameters  
Pulse generation variables  
Current shunt variables  
Calibration parameters  
Fundamental Energy Measurement Variables  
The table below describes each transfer variable for fundamental energy measurement. All variables are signed 32 bit  
integers. Accumulated variables such as WSUM are internally scaled so they have at least 2x margin before overflow when the  
integration time is 1 second. Additionally, the hardware will not permit output values to ‘fold back’ upon overflow.  
Page: 82 of 101  
© 2005-2008 TERIDIAN Semiconductor Corporation  
v1.0  
 