GR 1089–Core  
Second Level Lightning Surge Test  
The Second Level Lightning Surge Test, presented in Table 4.5, does not require the EUT  
to pass operationally, but GR 1089 does require that the EUT not become a fire,  
fragmentation, or electrical safety hazard. This is referred to as passing “non-operationally.”  
Table 4.5 Second Level Lightning Surge Test  
Surge  
Voltage  
(VPK  
Waveform  
(µs)  
Surge Current  
(A)  
Repetitions Each  
Polarity  
Test Connections  
Test  
)
(Table 4.1, Figure 4.1)  
1
±5000  
2x10  
500  
1
B
Notes:  
Primary protectors are removed.  
For EUT containing secondary voltage limiting and current limiting protectors, tests are to be performed at the indicated voltage(s)  
and repeated at a reduced voltage and current just below the operating threshold of the secondary protectors.  
Alternatively, a surge generator of 1.2x50 µs open-circuit voltage waveform (8x20 µs short-circuit current waveform) per  
IEEE C62.41 may be used. The current shall be limited by the inclusion of a series 8 resistor placed externally to the surge  
generator.  
AC Power Fault Tests  
Power companies and telephone operating companies often share telephone poles and  
trenches; therefore, network equipment is often subjected to the voltages seen on power  
lines. If direct contact between the telephone line and the primary power line occurs, the  
operating company’s network equipment may see as much as 600 V rms for five seconds,  
by which time the power company’s power system should clear itself. If direct contact  
occurs with the secondary power line, voltages will be limited to 277 V rms; however, these  
voltages may be seen indefinitely because the resultant current may be within the operating  
range of the power system, and the power system will not reset itself.  
Another risk involved with power lines is indirect contact. Because of the large magnetic  
fields created by the currents in the power lines, large voltages may be induced upon phone  
lines via electro-magnetic coupling. In this instance voltages should be limited to  
1000 V peak and 600 V rms using primary protectors, while the current will be limited by the  
current-carrying capacity of the 24-gauge wire.  
http://www.teccor.com  
+1 972-580-7777  
4 - 6  
© 2002 Teccor Electronics  
SIDACtor Data Book and Design Guide  
®