■ RELIABILITY DATA
1. Operating Temperature Range
Specified Value
X7R(-55℃~+125℃)
【Test Methods and Remarks】
Continuous use is available in this range.(reference temperature : 25℃)
2.Highest Operating temperature Range
Specified Value
X7R(-55℃~+125℃)
【Test Methods and Remarks】
Maximum ambient temperature at which capacitors can be continuously used with rated voltage applied.
3. Rated Voltage
Specified Value
Please refer to the page of the "PART NUMBERS".
【Test Methods and Remarks】
Continuous maximum applied voltage. If an AC voltage is loaded on a DC voltage, the sum of the two peak voltages should be lower than the rated voltage of the capacitor.
4. Shape and Dimensions
Specified Value
Please refer to the page of the "EXTERNAL DIMENSIONS".
5. Heat Treatmen(t ClassⅡ)
【Test Methods and Remarks】
Initial value shall be measured after test sample is heat-treated at 150+0/-10℃ for an hour and kept at room temperature for 24 ±2 hours.
6. Voltage Treatmen(t ClassⅡ)
【Test Methods and Remarks】
Initial value shall be measured after test sample is voltage-treated for an hour at temperature and voltage which are specified as test conditions, and kept at room temperature
for 24 ±2 hours.
7. Dielectric Withstanding Voltage(between terminals)
Specified Value
No abnormality.
【Test Methods and Remarks】
Applied voltage : Rated voltage × 2.5
Duration : 1 to 5 seconds.
Charging and discharging current shall be 50mA max.
8. Insulation Resistance
Specified Value
Larger than whichever smaller of 500 MΩ・µF or 104 MΩ
【Test Methods and Remarks】
Applied voltage : Rated voltage
Duration : 60±5 seconds.
Charging and discharging current shall be 50mA max.
9. Capacitance and Tolerance
Specified Value
Please refer to the page of the "PART NUMBERS".
【Test Methods and Remarks】
Measurement frequency :1KHz±10%(C≦10μF)
Measurement voltage:1±0.2Vrm(s C≦10μF)
0.5±0.1V(6.3V rated voltage)
Heat treatment specified in No.5 of the specification shall be conducted prior to measurement.
10. Q or Dissipation facto(r tanδ)
Specified Value
Please refer to the page of the "PART NUMBERS".
【Test Methods and Remarks】
Measurement frequency :1KHz±10%(C≦10μF)
Measurement voltage:1±0.2Vrm(s C≦10μF)
0.5±0.1V(6.3V rated voltage)
Heat treatment specified in No.5 of the specification shall be conducted prior to measurement. NO DC bias is applied.
11. Temperature Characteristic(without DC bias)
Specified Value
X7R(-55℃~+125℃):±15%
【Test Methods and Remarks】
Confirming to EIA RS-198-D(1991).
Heat treatment specified in No.5 of the specification shall be conducted prior to measurement.
Change of the muximum capacitance deviation in step 1 to 5. Temperature at step 1:+25℃
Temperature at step 2:minimum operating temperature
Temperature at step 3:+25℃
Temperature at step 4:maximum operating temperature Temperature at step 5:+25℃
12. Adhesive Force of Terminal Electrodes
Specified Value
Appearance:Terminal electrodes shall be no exfoliation or a sign of exfoliation.
【Test Methods and Remarks】
Solderlands refer to fig.1.
c
Note: Applying force : 10N for larger than 2125 size, 5N for 0603 size.
Case size
Duration : 30±5 seconds.
Dimension
1608
1.0
2125
3216
2.2
3225
2.2
a
b
c
1.2
4.0
b
3.0
5.0
5.0
a
1.2
1.65
2.0
2.9
fig.1
13. Vibration
Appearance:Initial performance shall be satisfied.
Capacitance Change:≤±7.5%
Q or Dissipation Factor:[Dissipation Factor]Initial value shall be satisfied.
Insulation Resistance;Initial value shall be satisfied.
Specified Value
【Test Methods and Remarks】
Heat treatment specified in No.5 of the specification shall be conducted prior to test. Measurement shall be conducted after test sample is heat treated as specified in No.5.
Solderlands refer to figure 1.
Direction of the vibration test: X, Y, Z each of 3 orientations for 2 hours respectyively(total 6 hours)ꢀ
Vibration frequency:10 ~55~10Hz(1 minutes each)
Total amplitude: 1.5 mm
Measurement after the test shall be made after test sample is kept at room temperature for 24 ±2 hours.
*This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
mlcc09_reli_e-01
mlcc09_reli-P1