9 - 40 V
0 - 40 V
30 A
Input:
Outputs:
Current:
Package:
Quarter-brick
Technical Specification
NQ40x40QGC30 ELECTRICAL CHARACTERISTICS (Continued)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24 V dc unless otherwise noted; full operating temperature range is -40 °C to +105 °C ambient temperature with appropriate power derating. Specifications
subject to change without notice.
Parameter
Vout Min. Typ. Max. Units Notes & Conditions
DYNAMIC CHARACTERISTICS
Output Voltage during Current Transient
For a Step Change in Output Current
Settling Time
All
1
V
(0.1 A/µs); 50%-75%-50% Iout max
To within 1.5% Vout nom.
All
5
ms
Turn on Transient
Startup delay
Rise Rate
Output Voltage Overshoot
FEATURE CHARACTERISTICS
Switching Frequency
All
All
All
2
0.4
ms
V/ms
V
Resistive load
"
"
0
All
240
250
260
kHz
ON/OFF Control
Negative Logic (N) ON/OFF Control
Off-State Voltage
On-State Voltage
Pull-Up Voltage
Pull-Up Resistance
Output Voltage Trim Range
Input/Output Over-Voltage Protection
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (TR-NWT-000332; Telcordia)
Calculated MTBF (MIL-HDBK-217F; MIL-217)
Field Demonstrated MTBF
All
All
All
All
All
All
All
All
1.8
0
3.3
0.8
V
V
V
kΩ
V
V
3.3
10
0
44
40
50
Measured Vout+ to common pins
Over full temp range
Average PCB Temperature
48
115
15
°C
°C
6
6
6
All
All
All
TBD
TBD
10 Hrs. 100% load, 200LFM, 40 °C Ta
10 Hrs. 100% load, 200LFM, 40 °C Ta
10 Hrs. See our website for details
STANDARDS COMPLIANCE
Parameter
STANDARDS COMPLIANCE
Notes & Conditions
UL/cUL 60950-1
Pending UL Approval File # E194341
EN60950-1
Certified by TUV
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
GR-1089-CORE
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)
Section 7 - electrical safety, Section 9 - bonding/grounding
Telcordia (Bellcore) GR-513
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
QUALIFICATION TESTING
Parameter
QUALIFICATION TESTING
Life Test
# Units Test Conditions
32
95% rated Vin and load, units at derating point, 1000 hours
Vibration
5
5
10
5
5
5
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day
MIL-STD-883, method 2003
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
15 pins
Note: Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply
robust, reliable product. Contact the factory for official product family qualification documents.
Product # NQ40x40QGC30
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-NQ4040W Rev. B
03/09/09