DC and AC parameters
M95640-W M95640-R M95640-DF
9
DC and AC parameters
This section summarizes the operating conditions and the DC/AC characteristics of the
device.
Table 9.
Symbol
Operating conditions (M95640-W, device grade 6)
Parameter Min.
Max.
Unit
VCC
TA
Supply voltage
Ambient operating temperature
2.5
5.5
85
V
–40
°C
Table 10. Operating conditions (M95640-R, device grade 6)
Symbol
Parameter
Min.
Max.
Unit
VCC
TA
Supply voltage
Ambient operating temperature
1.8
5.5
85
V
–40
°C
Table 11. Operating conditions (M95640-DF, device grade 6)
Symbol
Parameter
Min.
Max.
Unit
VCC
TA
Supply voltage
Ambient operating temperature
1.7
5.5
85
V
–40
°C
Table 12. AC measurement conditions
Symbol
Parameter
Min.
Max.
Unit
CL
Load capacitance
30
pF
ns
V
Input rise and fall times
25
Input pulse voltages
0.2 VCC to 0.8 VCC
0.3 VCC to 0.7 VCC
Input and output timing reference voltages
V
Figure 18. AC measurement I/O waveform
)NPUT VOLTAGE LEVELS
)NPUT AND OUTPUT
TIMING REFERENCE LEVELS
ꢊꢌꢉ 6
##
ꢊꢌꢂ 6
##
ꢊꢌꢃ 6
##
ꢊꢌꢆ 6
##
!)ꢊꢊꢉꢆꢇ#
32/47