 浏览型号M29W320EB70N6E的Datasheet PDF文件第13页浏览型号M29W320EB70N6E的Datasheet PDF文件第14页浏览型号M29W320EB70N6E的Datasheet PDF文件第15页浏览型号M29W320EB70N6E的Datasheet PDF文件第16页浏览型号M29W320EB70N6E的Datasheet PDF文件第18页浏览型号M29W320EB70N6E的Datasheet PDF文件第19页浏览型号M29W320EB70N6E的Datasheet PDF文件第20页浏览型号M29W320EB70N6E的Datasheet PDF文件第21页  
M29W320ET, M29W320EB  
the device enters Extended Block mode where all  
Bus Read or Program operations to the Boot Block  
addresses access the Extended Block. The Ex-  
tended Block (with the same address as the boot  
block) cannot be erased, and can be treated as  
one-time programmable (OTP) memory. In Ex-  
tended Block mode the Boot Blocks are not acces-  
sible.  
To exit from the Extended Block mode the Exit Ex-  
tended Block command must be issued.  
The Extended Block can be protected, however  
once protected the protection cannot be undone.  
Exit Extended Block Command  
The Exit Extended Block command is used to exit  
from the Extended Block mode and return the de-  
vice to Read mode. Four Bus Write operations are  
required to issue the command.  
Block Protect and Chip Unprotect Commands  
Groups of blocks can be protected against acci-  
dental Program or Erase. The Protection Groups  
are shown in APPENDIX A., Table 20. and Table  
21., Block Addresses. The whole chip can be un-  
protected to allow the data inside the blocks to be  
changed.  
Block Protect and Chip Unprotect operations are  
described in APPENDIX D.  
Table 4. Commands, 16-bit mode, BYTE = VIH  
Bus Write Operations  
Command  
1st  
2nd  
3rd  
4th  
5th  
6th  
Addr Data Addr Data Addr Data Addr Data Addr Data Addr Data  
1
3
X
F0  
Read/Reset  
555  
AA  
2AA  
2AA  
2AA  
55  
55  
55  
X
F0  
90  
(BA)  
555  
Auto Select  
3
555  
AA  
Program  
4
3
3
555  
555  
555  
AA  
50  
555  
PA1  
555  
A0  
PD1  
20  
PA  
PD  
Double Word Program  
Unlock Bypass  
PA0 PD0  
AA  
2AA  
PA  
55  
Unlock Bypass  
Program  
2
X
A0  
PD  
Unlock Bypass Reset  
Chip Erase  
2
6
X
90  
AA  
AA  
B0  
30  
X
00  
55  
55  
555  
2AA  
2AA  
555  
555  
80  
80  
555  
555  
AA  
AA  
2AA  
2AA  
55  
55  
555  
BA  
10  
30  
Block Erase  
6+ 555  
Erase Suspend  
Erase Resume  
1
1
1
3
4
BA  
BA  
55  
Read CFI Query  
Enter Extended Block  
Exit Extended Block  
98  
555  
555  
AA  
AA  
2AA  
2AA  
55  
55  
555  
555  
88  
90  
X
00  
Note: X Don’t Care, PA Program Address, PD Program Data, BA Any address in the Block. All values in the table are in hexadecimal.  
The Command Interface only uses A–1, A0-A10 and DQ0-DQ7 to verify the commands; A11-A20, DQ8-DQ14 and DQ15 are Don’t  
Care. DQ15A–1 is A–1 when BYTE is V or DQ15 when BYTE is V  
.
IH  
IL  