32 Mbit Concurrent SuperFlash
SST36VF3203 / SST36VF3204
Data Sheet
TABLE 7: SOFTWARE COMMAND SEQUENCE
Command
Sequence
1st Bus
Write Cycle
2nd Bus
Write Cycle
3rd Bus
Write Cycle
4th Bus
Write Cycle
5th Bus
Write Cycle
6th Bus
Write Cycle
Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2
555H
555H
555H
555H
XXXH
XXXH
555H
555H
AAH
AAH
AAH
AAH
B0H
30H
AAH
AAH
2AAH
2AAH
2AAH
2AAH
55H
55H
55H
55H
555H
555H
555H
555H
A0H
80H
80H
80H
WA3
555H
555H
555H
Data
AAH
AAH
AAH
Word-Program
Sector-Erase
Block-Erase
4
4
2AAH
2AAH
2AAH
55H
55H
55H
SAX
BAX
50H
30H
10H
555H
Chip-Erase
Erase-Suspend
Erase-Resume
Query Sec ID5
2AAH
2AAH
55H
55H
555H
555H
88H
A5H
SIWA6
Data
User Security ID
Word-Program
555H
AAH
2AAH
55H
555H
85H
XXXH 0000H
User Security ID
Program Lock-out7
4
Software ID Entry8,9
CFI Query Entry9
CFI Query Entry9
555H
555H
AAH
AAH
98H
AAH
2AAH
2AAH
55H
55H
BKX
90H
98H
555H
4
BKX
555H
4
BKX
55H
555H
2AAH
55H
555H
F0H
Software ID Exit/
CFI Exit/
Sec ID Exit10,11
XXH
F0H
Software ID Exit/
CFI Exit/
Sec ID Exit10,11
T7.1 1270
1. Address format A10-A0 (Hex), Addresses A20-A11 can be VIL or VIH, but no other value (unless otherwise stated), for the command
sequence when in x16 mode.
When in x8 mode, Addresses A20-A12, Address A-1, and DQ14-DQ8 can be VIL or VIH, but no other value (unless otherwise stated), for
the command sequence.
2. DQ15-DQ8 can be VIL or VIH, but no other value, for the command sequence
3. WA = Program word address
4. SAX for Sector-Erase; uses A20-A11 address lines
BAX for Block-Erase; uses A20-A15 address lines
BKX for Bank Address; uses A20-A18 address lines
5. For SST36VF3203 the Security ID Address Range is: (x16 mode) = 100000H to 100087H,(x8 mode) = 100000H to 10010FH
SST ID is read at Address Range(x16 mode) = 100000H to 100007H (x8 mode) = 100000H to 10000FH
User ID is read at Address Range(x16 mode) = 100008H to 100087H (x8 mode) = 100010H to 10010FH
Lock status is read at Address 1000FFH (x16) or 1001FFH (x8). Unlocked: DQ3 = 1 / Locked: DQ3 = 0.
For SST36VF3204 the Security ID Address Range is:(x16 mode) = 000000H to 000087H, (x8 mode) = 000000H to 00010FH
SST ID is read at Address Range (x16 mode) = 000000H to 000007H (x8 mode) = 000000H to 00000FH
User ID is read at Address Range (x16 mode) = 000008H to 000087H (x8 mode) = 000010H to 00010FH
Lock Status is read at Address 0000FFH (x16) or 0001FFH (x8). Unlocked: DQ3 = 1 / Locked: DQ3 = 0
6. SIWA = Valid Word addresses for user Sec ID
For SST36VF3203 User ID valid Address Range is (x16 mode) = 100008H-100087H (x8 mode) = 100010H-10010FH.
For SST36VF3204 User ID valid Address Range is (x16 mode) = 000008H-000087H (x8 mode) = 000010H-00010FH.
All 4 cycles of User Security ID Program and Program Lock-out must be completed before going back to Read-Array mode.
7. The User Security ID Program Lock-out command must be executed in x16 mode (BYTE#=VIH).
8. The device does not remain in Software Product Identification mode if powered down.
9. A20, A19, and A18 = BKX (Bank Address): address of the bank that is switched to Software ID/CFI Mode
With A17-A1 = 0;SST Manufacturer’s ID = 00BFH, is read with A0 = 0
SST36VF3203 Device ID = 7354H, is read with A0 = 1
SST36VF3204 Device ID = 7353H, is read with A0 = 1
10. Both Software ID Exit operations are equivalent
11. If users never lock after programming, User Sec ID can be programmed over the previously unprogrammed bits (data=1) using the
User Sec ID mode again (the programmed “0” bits cannot be reversed to “1”).
©2005 Silicon Storage Technology, Inc.
S71270-03-000
7/06
13