 浏览型号AM29BDS320GTC9VMI的Datasheet PDF文件第35页浏览型号AM29BDS320GTC9VMI的Datasheet PDF文件第36页浏览型号AM29BDS320GTC9VMI的Datasheet PDF文件第37页浏览型号AM29BDS320GTC9VMI的Datasheet PDF文件第38页浏览型号AM29BDS320GTC9VMI的Datasheet PDF文件第40页浏览型号AM29BDS320GTC9VMI的Datasheet PDF文件第41页浏览型号AM29BDS320GTC9VMI的Datasheet PDF文件第42页浏览型号AM29BDS320GTC9VMI的Datasheet PDF文件第43页  
P r e l i m i n a r y  
Write Operation Status  
The device provides several bits to determine the status of a program or erase  
operation: DQ2, DQ3, DQ5, DQ6, and DQ7. Table 16, “Write Operation Status,”  
on page 42 and the following subsections describe the function of these bits. DQ7  
and DQ6 each offers a method for determining whether a program or erase op-  
eration is complete or in progress.  
DQ7: Data# Polling  
The Data# Polling bit, DQ7, indicates to the host system whether an Embedded  
Program or Erase algorithm is in progress or completed, or whether a bank is in  
Erase Suspend. Data# Polling is valid after the rising edge of the final WE# pulse  
in the command sequence.  
During the Embedded Program algorithm, the device outputs on DQ7 the com-  
plement of the datum programmed to DQ7. This DQ7 status also applies to  
programming during Erase Suspend. When the Embedded Program algorithm is  
complete, the device outputs the datum programmed to DQ7. The system must  
provide the program address to read valid status information on DQ7. If a pro-  
gram address falls within a protected sector, Data# Polling on DQ7 is active for  
approximately 1 µs, then that bank returns to the read mode.  
During the Embedded Erase algorithm, Data# Polling produces a “0” on DQ7.  
When the Embedded Erase algorithm is complete, or if the bank enters the Erase  
Suspend mode, Data# Polling produces a “1” on DQ7. The system must provide  
an address within any of the sectors selected for erasure to read valid status in-  
formation on DQ7.  
After an erase command sequence is written, if all sectors selected for erasing  
are protected, Data# Polling on DQ7 is active for approximately 100 µs, then the  
bank returns to the read mode. If not all selected sectors are protected, the Em-  
bedded Erase algorithm erases the unprotected sectors, and ignores the selected  
sectors that are protected. However, if the system reads DQ7 at an address within  
a protected sector, the status may not be valid.  
Just prior to the completion of an Embedded Program or Erase operation, DQ7  
may change asynchronously with DQ6–DQ0 while Output Enable (OE#) is as-  
serted low. That is, the device may change from providing status information to  
valid data on DQ7. Depending on when the system samples the DQ7 output, it  
may read the status or valid data. Even if the device has completed the program  
or erase operation and DQ7 has valid data, the data outputs on DQ6–DQ0 may  
be still invalid. Valid data on DQ7–DQ0 will appear on successive read cycles.  
Table 16 shows the outputs for Data# Polling on DQ7. Figure 3 shows the Data#  
Polling  
algorithm.  
Figure 27,  
“Data#  
Polling  
Timings  
(During Embedded Algorithm),on page 64 in the AC Characteristics section  
shows the Data# Polling timing diagram.  
October 1, 2003 27243B1  
Am29BDS320G  