CXD2510Q
$7X commands
Auto sequence track jump count setting
Data 1
Data 2
Data 3
Data 4
Command
D3 D2 D1 D0 D3 D2 D1 D0 D3 D2 D1 D0 D3 D2 D1 D0
215 214 213 212 211 210 29 28 27 26 25 24 23 22 21 20
Auto sequencer
track jump count setting
This command is used to set N when a 2N track jump is executed, and the jump count setting when fine
search is executed for auto sequence.
• The maximum track count is 65,535, but note that with 2N track jumps the maximum track jump count is
determined by the mechanical limitations of the optical system.
• When N is from 0 to 15, the number of 2N track jumps is counted according to the signals input from the
CNIN pin. When N is 16 or over, it is counted according to the signals input from the MIRR pin.
$8X commands
Data 1
Data 2
Command
D3
D2
D1
D0
D3
D2
D1
D0
0
MODE
specification
DOUT
Mute
D.out
Mute-F
CDROM
WSEL VCO SEL ASHS
SOCT
Command bit
CDROM = 1
C2PO timing
Processing
See the Timing
Chart 1-3
CDROM mode; average value interpolation and pre-value
hold are not performed.
See the Timing
Chart 1-3
Audio mode; average value interpolation and pre-value
hold are performed.
CDROM = 0
Command bit
DOUT Mute = 1
DOUT Mute = 0
Processing
When Digital out is on (MD2 pin = 1), DOUT output is muted.
When Digital out is on, DOUT output is not muted.
Command bit
Processing
D. out Mute F = 1 When Digital out is on (MD2 pin = 1), DA output is muted.
D. out Mute F = 0 DA output mute is not affected when Digital out is either on or off.
– 12 –