CXD2510Q
The meaning of the data for each address is explained below.
$4X commands
Register name
4
Data 1
Data 2
Data 3
Command
MAX timer value
Timer range
AS3
AS2
AS1
AS0
MT3
MT2
MT1
MT0 LSSL
0
0
0
Command
AS3
0
AS2
AS1
0
AS0
0
Cancel
0
1
1
0
0
1
FineSearch
Focus-On
0
0
RXF
1
0
1
1 TrackJump
10 TrackJump
2N TrackJump
1
0
RXF
RXF
RXF
1
1
1
0
RXF = 0 Forward
RXF = 1 Reverse
• When the FOCUS-ON command ($47) is canceled, $02 is sent and the auto sequence is interrupted.
• When the TRACK JUMP commands ($44 to $45, $48 to $4D) are canceled, $25 is sent and the auto
sequence is interrupted.
Max. timer value
Timer range
MT3
23.2ms
1.49s
MT2
11.6ms
0.74s
MT1
5.8ms
0.37s
MT0
2.9ms
0.18s
LSSL
0
0
0
0
0
0
0
0
1
0
0
• To invalidate the MAX timer, set the MAX timer value to 0.
$5X commands
Timer
TR3
TR2
TR1
TR0
Blind (A, E), Overflow (C, G)
0.18ms
0.09ms
0.045ms
0.022ms
0.045ms
Brake (B)
0.36ms
0.18ms
0.09ms
$6X commands
Data 1
KICK (D)
SD2 SD1
Data 2
KICK (F)
KF2 KF1
Register name
6
SD3
SD0
KF3
KF0
Timer
SD3
SD2
11.6ms
5.8ms
SD1
SD0
2.9ms
1.45ms
When executing KICK (D) $44 or $45
When executing KICK (D) $4C or $4D
23.2ms
11.6ms
5.8ms
2.9ms
Timer
KF3
KF2
KF1
KF0
KICK (F)
0.72ms
0.36ms
0.18ms
0.09ms
– 11 –