High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface  
Datasheet  
14.5.3.9  
Switch Engine VLAN Write Data Register (SWE_VLAN_WR_DATA)  
Register #:  
180Ch  
Size:  
32 bits  
This register is used write the VLAN or Port VID tables.  
BITS  
DESCRIPTION  
TYPE  
DEFAULT  
31:18  
17:0  
RESERVED  
RO  
-
Port Default VID and Priority  
R/W  
0b  
When the port VID table is selected (PVIDnVLAN=1 of the Switch Engine  
VLAN Command Register (SWE_VLAN_CMD)), bits 11:0 of this field specify  
the default VID for the port and bits 14:12 specify the default priority. All  
other bits of this field are reserved. These bits are used when a packet is  
received without a VLAN tag or with a NULL VLAN ID. By default, the VID  
and priority for all three ports is 0.  
Note:  
Values of 0 and FFFh should not be used since they are special  
VLAN IDs per the IEEE 802.3Q specification.  
VLAN Data  
When the VLAN table is selected (PVIDnVLAN=0 of the Switch Engine  
VLAN Command Register (SWE_VLAN_CMD)), the bits form the VLAN  
table entry as follows:  
BITS  
17  
DESCRIPTION  
DEFAULT  
Member Port 2  
0b  
Indicates the configuration of Port 2 for this VLAN entry.  
1 = Member - Packets with a VID that matches this entry  
are allowed on ingress. The port is a member of the  
broadcast domain on egress.  
0 = Not a Member - Packets with a VID that matches this  
entry are filtered on ingress unless the Admit Non Member  
bit in the Switch Engine Admit Non Member Register  
(SWE_ADMT_N_MEMBER) is set for this port. The port is  
not a member of the broadcast domain on egress.  
16  
Un-Tag Port 2  
0b  
When this bit is set, packets received on Port 2 with a VID  
that matches this entry will have their tag removed when re-  
transmitted by egress ports that are designated as Hybrid  
ports via the Buffer Manager Egress Port Type Register  
(BM_EGRSS_PORT_TYPE).  
15  
14  
Member Port 1  
0b  
0b  
See description for Member Port 2.  
Un-Tag Port 1  
See description for Un-Tag Port 2.  
13  
Member Port 0 (Host MAC)  
See description for Member Port 2.  
0b  
12  
Un-Tag Port 0 (Host MAC)  
See description for Un-Tag Port 2.  
0b  
11:0  
VID  
000h  
These bits specify the VLAN ID associated with this VLAN  
entry.  
To disable a VLAN entry, a value of 0 should be used.  
Note:  
A value of 0 is considered a NULL VLAN and  
should not normally be used other than to  
disable a VLAN entry.  
Note:  
A value of 3FFh is considered reserved by IEEE  
802.1Q and should not be used.  