10/100 Non-PCI Ethernet Single Chip MAC + PHY  
Datasheet  
8.19  
Bank 2 - Pointer Register  
OFFSET  
NAME  
TYPE  
SYMBOL  
PTR  
READ/WRITE  
NOT EMPTY IS  
A READ ONLY  
BIT  
6
POINTER REGISTER  
HIGH  
RCV  
AUTO  
INCR.  
READ  
0
ETEN  
NOT  
POINTER HIGH  
BYTE  
EMPTY  
0
0
0
0
0
0
0
0
0
LOW  
POINTER LOW  
BYTE  
0
0
0
0
0
0
POINTER REGISTER - The value of this register determines the address to be accessed within the  
transmit or receive areas. It will auto-increment on accesses to the data register when AUTO INCR.  
is set. The increment is by one for every byte access, by two for every word access, and by four for  
every double word access. When RCV is set the address refers to the receive area and uses the  
output of RX FIFO as the packet number, when RCV is clear the address refers to the transmit area  
and uses the packet number at the Packet Number Register.  
READ - Determines the type of access to follow. If the READ bit is high the operation intended is a  
read. If the READ bit is low the operation is a write. Loading a new pointer value, with the READ bit  
high, generates a pre-fetch into the Data Register for read purposes.  
Readback of the pointer will indicate the value of the address last accessed by the CPU (rather than  
the last pre-fetched). This allows any interrupt routine that uses the pointer, to save it and restore it  
without affecting the process being interrupted. The Pointer Register should not be loaded until the  
Data Register FIFO is empty. The NOT EMPTY bit of this register can be read to determine if the  
FIFO is empty. On reads, if ARDY is not connected to the host, the Data Register should not be read  
before 370ns after the pointer was loaded to allow the Data Register FIFO to fill.  
If the pointer is loaded using 8 bit writes, the low byte should be loaded first and the high byte last.  
ETEN - When set enables EARLY Transmit underrun detection. Normal operation when clear.  
NOT EMPTY - When set indicates that the Write Data FIFO is not empty yet. The CPU can verify that  
the FIFO is empty before loading a new pointer value. This is a read only bit.  
Note: If AUTO INCR. is not set, the pointer must be loaded with a dword aligned value.  