Table 38 - EPP Pin Descriptions  
EPP  
SIGNAL  
EPP NAME  
nWrite  
TYPE  
EPP DESCRIPTION  
This signal is active low. It denotes a write operation.  
nWRITE  
PD<0:7>  
INTR  
O
Address/Data  
Interrupt  
I/O  
I
Bi-directional EPP byte wide address and data bus.  
This signal is active high and positive edge triggered. (Pass  
through with no inversion, Same as SPP).  
WAIT  
nWait  
I
This signal is active low. It is driven inactive as a positive  
acknowledgement from the device that the transfer of data  
is completed. It is driven active as an indication that the  
device is ready for the next transfer.  
DATASTB nData Strobe  
RESET nReset  
O
O
O
This signal is active low. It is used to denote data read or  
write operation.  
This signal is active low. When driven active, the EPP device  
is reset to its initial operational mode.  
ADDRSTB nAddress  
Strobe  
This signal is active low. It is used to denote address read  
or write operation.  
PE  
Paper End  
I
I
Same as SPP mode.  
Same as SPP mode.  
SLCT  
Printer  
Selected  
Status  
nERR  
PDIR  
Error  
I
Same as SPP mode.  
Parallel Port  
Direction  
O
This output shows the direction of the data transfer on the  
parallel port bus. A low means an output/write condition and  
a high means an input/read condition. This signal is  
normally a low (output/write) unless PCD of the control  
register is set or if an EPP read cycle is in progress.  
Note 1: SPP and EPP can use 1 common register.  
Note 2: nWrite is the only EPP output that can be over-ridden by SPP control port during an EPP  
cycle. For correct EPP read cycles, PCD is required to be a low.  