performed, the trailing edge of IOW latches the  
data for the duration of the EPP write cycle.  
During a READ operation, PD0 - PD7 ports are  
read, the leading edge of IOR causes an EPP  
ADDRESS READ cycle to be performed and the  
data output to the host CPU, the deassertion of  
ADDRSTB latches the PData for the duration of  
the IOR cycle. This register is only available in  
EPP mode.  
BIT 1 AUTOFD - AUTOFEED  
This bit is inverted and output onto the  
nAUTOFD output. A logic “1” causes the printer  
to generate a line feed after each line is printed.  
A logic “0” means no autofeed.  
BIT 2 nINIT - nINITIATE OUTPUT  
This bit is output onto the nINIT output without  
inversion.  
EPP DATA PORT 0  
ADDRESS OFFSET = 04H  
BIT 3 SLCTIN - PRINTER SELECT INPUT  
This bit is inverted and output onto the nSLCTIN  
output. A logic “1” on this bit selects the printer;  
a logic “0” means the printer is not selected.  
The EPP Data Port 0 is located at an offset of  
'04H' from the base address. The data register  
is cleared at initialization by RESET. During a  
WRITE operation, the contents of DB0-DB7 are  
buffered (non inverting) and output onto the PD0  
- PD7 ports, the leading edge of nIOW causes  
an EPP DATA WRITE cycle to be performed,  
the trailing edge of IOW latches the data for the  
duration of the EPP write cycle. During a READ  
operation, PD0 - PD7 ports are read, the leading  
edge of IOR causes an EPP READ cycle to be  
performed and the data output to the host CPU,  
the deassertion of DATASTB latches the PData  
for the duration of the IOR cycle. This register  
is only available in EPP mode.  
BIT 4 IRQE - INTERRUPT REQUEST ENABLE  
The interrupt request enable bit when set to a  
high level may be used to enable interrupt  
requests from the Parallel Port to the CPU. An  
interrupt request is generated on the IRQ port by  
a positive going nACK input. When the IRQE  
bit is programmed low the IRQ is disabled.  
BIT  
5
PCD  
-
PARALLEL CONTROL  
DIRECTION  
Parallel Control Direction is not valid in printer  
mode. In printer mode, the direction is always  
out regardless of the state of this bit. In bi-  
directional, EPP or ECP mode, a logic 0 means  
that the printer port is in output mode (write); a  
logic 1 means that the printer port is in input  
mode (read).  
EPP DATA PORT 1  
ADDRESS OFFSET = 05H  
The EPP Data Port 1 is located at an offset of  
'05H' from the base address. Refer to EPP  
DATA PORT 0 for a description of operation.  
This register is only available in EPP mode.  
Bits 6 and 7 during a read are a low level, and  
cannot be written.  
EPP ADDRESS PORT  
ADDRESS OFFSET = 03H  
EPP DATA PORT 2  
The EPP Address Port is located at an offset of  
'03H' from the base address. The address  
register is cleared at initialization by RESET.  
During a WRITE operation, the contents of DB0-  
DB7 are buffered (non inverting) and output onto  
the PD0 - PD7 ports, the leading edge of nIOW  
causes an EPP ADDRESS WRITE cycle to be  
ADDRESS OFFSET = 06H  
The EPP Data Port 2 is located at an offset of  
'06H' from the base address. Refer to EPP  
DATA PORT 0 for a description of operation.  
This register is only available in EPP mode.  