 浏览型号FDC37B776的Datasheet PDF文件第138页浏览型号FDC37B776的Datasheet PDF文件第139页浏览型号FDC37B776的Datasheet PDF文件第140页浏览型号FDC37B776的Datasheet PDF文件第141页浏览型号FDC37B776的Datasheet PDF文件第143页浏览型号FDC37B776的Datasheet PDF文件第144页浏览型号FDC37B776的Datasheet PDF文件第145页浏览型号FDC37B776的Datasheet PDF文件第146页  
Table 55 - Logical Device Registers  
ADDRESS DESCRIPTION  
LOGICAL DEVICE  
REGISTER  
STATE  
Interrupt Select  
(0x70,0x72) 0x70 is implemented for each logical device.  
Refer to Interrupt Configuration Register  
description. Only the keyboard controller  
uses Interrupt Select register 0x72. Unused  
register (0x72) will ignore writes and return  
zero when read. Interrupts default to edge  
high (ISA compatible).  
C
Defaults :  
0x70 = 0x00,  
on Vcc POR or  
Reset_Drv  
0x72 = 0x00,  
on Vcc POR or  
Reset_Drv  
(0x71,0x73) Reserved - not implemented. These register  
locations ignore writes and return zero when  
read.  
DMA Channel Select  
(0x74,0x75) Only 0x74 is implemented for FDC, Serial  
C
Port 2 and Parallel port.  
0x75 is not  
Default = 0x04  
on Vcc POR or  
Reset_Drv  
implemented and ignores writes and returns  
zero when read. Refer to DMA Channel  
Configuration.  
32-Bit Memory Space  
Configuration  
(0x76-0xA8) Reserved - not implemented. These register  
locations ignore writes and return zero when  
read.  
Logical Device  
(0xA9-0xDF) Reserved - not implemented. These register  
locations ignore writes and return zero when  
read.  
C
C
C
Logical Device  
Configuration  
(0xE0-0xFE) Reserved  
defined  
-
Vendor Defined (see SMSC  
Logical Device Configuration  
Registers).  
Reserved  
0xFF  
Reserved  
Note 1: A logical device will be active and powered up according to the following equation:  
DEVICE ON (ACTIVE) = (Activate Bit SET or Pwr/Control Bit SET).  
The Logical device's Activate Bit and its Pwr/Control Bit are linked such that setting or  
clearing one sets or clears the other.  
Note 2: If the I/O Base Addr of the logical device is not within the Base I/O range as shown in the  
Logical Device I/O map, then read or write is not valid and is ignored.  
Note 3: The Activate Register for Logical Device 5 (Serial Port 2) is reset by VTR POR only.  
142  