Environmental Monitoring and Control Device  
Datasheet  
BIT  
0
NAME  
START  
R/W  
R/W  
DEFAULT  
0
DESCRIPTION  
When software writes a 1 to this bit, the EMC6D100/EMC6D101 enables  
monitoring and PWM output control functions based on the limit and  
parameter registers. Before this bit is set, the part does not update register  
values. Whenever this bit is set to 0, the monitoring and PWM output  
control functions are based on the default limits and parameters,  
regardless of the current values in the limit and parameter registers. The  
EMC6D100/EMC6D101 preserves the values currently stored in the limit  
and parameter registers when this bit is set or cleared. This bit becomes  
read only when the Lock bit is set.  
Note: When this bit is 0, all fans are on full 100% duty cycle, i.e., PWM  
pins are high (OD) for 255 clocks, low for 1 clock. When this bit is 0, the  
part is not monitoring.  
It is expected that all limit and parameter registers will be set by BIOS or  
application software prior to setting this bit because these registers cannot  
be written once the start bit is set.  
Setting this bit to 1 locks specified limit and parameter registers. Once this  
bit is set, limit and parameter registers become read only and will remain  
locked until the device is powered off. This register bit becomes read only  
once it is set.  
The EMC6D100/EMC6D101 sets this bit automatically after the part is fully  
powered up, has completed the power-up-reset process, and after all A/D  
converters are functioning (all bias conditions for the A/Ds have stabilized  
and the A/Ds are in operational mode). (Always reads back ‘1’.)  
1
2
LOCK  
R/W  
R
0
0
READY  
3
OVRID  
R/W  
R
0
0
If this bit is set to 1, all PWM outputs go to 100% duty cycle regardless of  
whether or not the lock bit is set.  
4-7  
Reserved  
Reserved  
Note: There is a start-up time of up to 82ms for monitoring after the start bit is set to ‘1’, during which time  
the reading registers are not valid.  
The following summarizes the operation of the part based on the Start bit:  
1. If Start bit = '0' then:  
a) Fans are set to Full On.  
b) No voltage, temperature, or fan tach monitoring is performed. The values in the reading registers  
will be N/A (Not Applicable), which means these values will not be considered valid readings until  
the Start bit = '1'. The exception to this is the Tachometer reading registers, which always give  
the actual reading on the TACH pins.  
c) No Status bits are set.  
2. If Start bit = '1' then:  
a) All fan control and monitoring will be based on the current values in the registers. There is no  
need to preserve the default values after software has programmed these registers because no  
monitoring or auto fan control will be done when Start bit = '0'.  
b) Status bits may be set.  
c) The limit and parameter registers are read-only when the start bit is 1. Only the Current PWM  
Duty Cycle and Ready/Lock /Start registers are writeable when the associated fan is in manual  
mode. The INTEN bit in register 7Ch is also writeable when the start bit is set.  
Note: Once programmed, the register values will be saved when start bit is reset to ‘0’.  
SMSC EMC6D100/EMC6D101  
Page 45  
Rev. 09-09-04  
DATASHEET  