Environmental Monitoring and Control Device  
Datasheet  
BIT 7  
(MSB)  
BIT 0  
(LSB)  
REGISTER  
ADDRESS  
READ/  
WRITE  
REGISTER  
NAME  
DEFAULT  
VALUE  
BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1  
PWM Duty  
31h  
32h  
R/W1  
R/W1  
Fan2 Current  
7
7
6
6
5
5
4
4
3
3
2
2
1
1
0
0
N/A  
N/A  
PWM Duty  
Fan3 Current  
PWM Duty  
Note 1: these registers are only writeable when the associated fan is in manual mode. These registers  
become read only when the Lock bit is set. Any further attempts to write to these registers shall have no  
effect.  
The Current PWM Duty registers store the duty cycle that the EMC6D100/EMC6D101 Chip is currently  
driving the PWM signals at. At initial power-on, the duty cycle is 100% and thus, when read, this register  
will return FFh. After the Ready/Lock/Start Register Start bit is set, this register and the PWM signals are  
updated based on the algorithm described in the Auto Fan Control Operating Mode section, unless the  
associated fan is in manual mode – see below.  
When read, the Current PWM Duty registers return the current PWM duty cycle for the respective PWM  
signal.  
These registers are read only – a write to these registers has no effect.  
Note: If the current PWM duty cycle registers are written while the part is not in manual mode and the start  
bit is zero, data will be stored in a hidden registers that will only be active and observable when the start bit  
is set. While the part is not in manual mode and the start bit is zero, the current PWM duty cycle registers  
will read back FFh.  
8.7.1 MANUAL MODE  
In manual mode, the current duty cycle registers are writeable to control the PWMs. In manual mode,  
when the start bit is set to 1, the current duty cycle registers are writeable to control the PWMs. Also in  
manual mode, when the lock bit is set to 1, the current duty cycle registers are Read-Only.  
The PWM duty cycle is represented as follows:  
Table 8.3 - PWM Duty vs. Register Reading  
CURRENT DUTY  
VALUE (DECIMAL)  
VALUE (HEX)  
00h  
0%  
0
25%  
50%  
64  
40h  
80h  
FFh  
128  
255  
100%  
During spin-up, the PWM duty cycle is reported as 0%.  
SMSC EMC6D100/EMC6D101  
Page 43  
Rev. 09-09-04  
DATASHEET  