RPM-Based Fan Controller with HW Thermal Shutdown  
Datasheet  
„
‘1’ - The External Diode channels have digital averaging disabled. The temperature data is the last  
measured data.  
Bits 3-2 - QUEUE[1:0] - Determines the number of consecutive out of limit conditions that are  
necessary to trigger an interrupt. Each measurement channel has a separate fault queue associated  
with the high limit, low limit, and diode fault condition.  
APPLICATION NOTE: If the fault queue for any channel is currently active (i.e. an out of limit condition has been  
detected and caused the fault queue to increment) then changing the settings will not take  
effect until the fault queue is zeroed. This occurs by the ALERT pin asserting or the out of  
limit condition being removed.  
Table 6.16 Fault Queue  
QUEUE[1:0]  
1
0
NUMBER OF CONSECUTIVE OUT OF LIMIT CONDITIONS  
0
0
1
1
0
1
0
1
1 (disabled)  
2
3
4 (default)  
Bit 1 - 0 - CONV[1:0] - determines the conversion rate of the temperature monitoring. This conversion  
rate does not affect the fan driver. The supply current from VDD_3V is nominally dependent upon the  
conversion rate and the average current will increase as the conversion rate increases.  
Table 6.17 Conversion Rate  
CONV[1:0]  
1
0
CONVERSION RATE  
0
0
1
1
0
1
0
1
1 / sec  
2 / sec  
4 / sec (default)  
Continuous  
The Configuration 2 Register is software locked.  
6.12  
Interrupt Status Register  
Table 6.18 Interrupt Status Register  
B6 B5 B4 B3  
ADDR  
R/W REGISTER  
B7  
B2  
B1  
B0  
DEFAULT  
Interrupt  
Status  
23h  
R-C  
-
TCRIT GPIO  
FAN  
HIGH  
LOW  
FAULT  
00h  
Register  
SMSC EMC2103  
Revision 0.85 (01-29-08)  
DATA4S9HEET