RPM-Based Fan Controller with HW Thermal Shutdown  
Datasheet  
„
„
‘0’ (default) - the External Diode 2 channel high limit will not be linked to the SYS_SHDN pin. If the  
temperature meets or exceeds the limit, the ALERT pin will be asserted normally.  
‘1’ - the External Diode 2 channel high limit will be linked to the SYS_SHDN pin. If the temperature  
meets or exceeds the limit then the SYS_SHDN pin will be asserted. The ALERT pin will be  
asserted normally.  
Bit 1 - SYS1 - Enables the high temperature limit for the External Diode 1 channel to trigger the Critical  
/ Thermal Shutdown circuitry (see Section 5.1).  
„
‘0’ (default) - The External Diode 1 channel high limit will not be linked to the SYS_SHDN pin. If  
the temperature meets or exceeds the limit, the ALERT pin will be asserted normally.  
„
‘1’ - The External Diode 1 channel high limit will be linked to the SYS_SHDN pin. If the temperature  
meets or exceeds the limit then the SYS_SHDN pin will be asserted. The ALERT pin will be  
asserted normally.  
Bit 0 - APD (EMC2103-2 only) - This bit enables the Anti-parallel diode functionality on the External  
Diode 3 pins (DP3 and DN3).  
„
‘0’ (default) - The Anti-parallel diode functionality is disabled. The External Diode 2 channel can be  
configured for any type of diode  
„
‘1’ - The Anti-parallel diode functionality is enabled. Both the External Diode 2 and 3 channels are  
configured to support a diode or diode connected transistor (such as a 2N3904).  
APPLICATION NOTE: When the APD diode is enabled, there will be a delay of a full temperature update before  
any comparisons and functionality associated with the External Diode 3 channel will be  
implemented. This includes the SYS3 bit operation, limit comparisons, and look up table  
comparisons.  
The Configuration Register is software locked.  
6.11  
Configuration 2 Register  
Table 6.15 Configuration 2 Register  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
DIS_D  
YN  
DIS_  
TO  
DIS_  
AVG  
21h  
R/W  
Config 2  
-
QUEUE[1:0]  
CONV[1:0]  
0Eh  
The Configuration 2 Register controls conversion rate of the temperature monitoring as well as the  
fault queue.  
Bit 6 - DIS_DYN - Disables the Dynamic Averaging Feature.  
„
‘0’ (default) - The Dynamic Averaging function is enabled. The conversion time for all temperature  
channels is scaled based on the chosen conversion rate to maximize accuracy and immunity to  
random temperature measurement variation.  
„
‘1’ - The Dynamic Averaging function is disabled. The conversion time for all temperature channels  
is fixed regardless of the chosen conversion rate.  
Bit 5 - DIS_TO - Disables the SMBus time out function.  
„
„
‘0’ (default) - The SMBus time out function is enabled.  
‘1’ - The SMBus time out function is disabled allowing the device to be fully I2C compliant.  
Bit 4 - DIS_AVG - Disables digital averaging of the External Diode channels.  
„
‘0’ (default) - The External Diode channels have digital averaging enabled. The temperature data  
is the average of the previous four measurements.  