RPM-Based Fan Controller with HW Thermal Shutdown  
Datasheet  
6.3  
Critical/Thermal Shutdown Temperature Register  
Table 6.4 Critical/Thermal Shutdown Temperature Register  
REGISTER B7 B6 B5 B4 B3 B2 B1  
64 32 16  
ADDRESS  
B0  
DEFAULT  
04h  
Critical/Therm Sign  
al Shutdown  
8
4
2
1
7Fh  
(+127°C)  
Temperature  
The Critical/Thermal Shutdown Temperature Register is a read-only register that stores the Voltage  
Programmable Threshold temperature used in the Thermal / Critical Shutdown circuitry. The contents  
of the register reflect the calculated temperature based on the TRIP_SET voltage. This register is  
updated at the end of every monitoring cycle based on the current value of TRIP_SET. The register  
value reflects the exact threshold temperature.  
The data format will match the selected format of the temperature data registers as shown in Table 6.3.  
6.4  
Configuration Register  
Table 6.5 Configuration Register  
ADDRESS  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
20h  
Configuration QUEUE[1:0] SYS3  
SYS2 SYS1  
FORMAT  
-
LOCK  
80h  
The Configuration Register controls the basic functionality of the EMC2102. The bits are described  
below. The Configuration Register is software locked.  
Bit 7-6 - QUEUE[1:0] - determines how many consecutive out-of-limit errors must occur on the  
hardware selected and software enabled temperature channels before the SYS_SHDN# pin is  
asserted (see Table 5.2). The queue applies to all enabled channels simultaneously and will trigger the  
SYS_SHDN# pin if there are four consecutive measurements with any or all channels exceeding their  
corresponding limits.  
Table 6.6 Fault Queue  
QUEUE1:0]  
1
0
NUMBER OF FAULTS  
0
0
1
1
0
1
0
1
1
2
4 (default)  
8
Bit 5 - SYS3 - enables the high temperature limit for the External Diode 3 channel to trigger the Critical  
/ Thermal Shutdown circuitry (see Section 5.7).  
„
‘0’ (default) - the External Diode 3 channel high limit will not be linked to the SYS_SHDN# pin. If  
the temperature exceeds the limit, the ALERT# pin will be asserted normally.  