High-Side Current-Sense and Internal 1°C Temperature Monitor
Datasheet
‘1’ -The device is not measuring the source voltage and sense voltage. It will update VSENSE and
VSOURCE registers when a One-Shot command is given.
5.6
Conversion Rate Register
Table 5.6 Conversion Rate Register
ADDR
R/W
REGISTER
B7
B6
B5
B4
B3
B2
B1
B0
DEFAULT
04h
0Ah
R/W
Conversion
Rate
-
-
-
-
T_CONV[2:0]
06h
(4/sec)
The Conversion Rate Register controls how often the VSOURCE and temperature measurement
channels are updated and compared against the limits. This register is fully accessible at either
address.
Bits 2-0 - T_CONV[2:0] - Determines the conversion rate as shown in Table 5.7. This conversion rate
applies to temperature measurement and source voltage measurement.
Table 5.7 Conversion Rate
T_CONV[2:0]
2
1
0
CONVERSION RATE
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
1 per 16 sec
1 per 8 sec
1 per 4 sec
1 per 2 sec
1 per sec
2 per sec
4 per sec (default)
8 per sec
5.7
Temperature Limit Registers
Table 5.8 Temperature Limit Registers
ADDR
R/W
REGISTER
B7
B6
B5
B4
B3
B2
B1
B0
DEFAULT
05h
0Bh
06h
0Ch
R/W
Internal Diode
High Limit
Sign
64
32
16
8
4
2
1
55h
(85°C)
R/W
Internal Diode
Low Limit
Sign
64
32
16
8
4
2
1
80h
(-128°C)
SMSC EMC1701
Revision 1.2 (09-27-10)
DATA3S3HEET