10 Mbps ARCNET (ANSI 878.1) Controller with 2Kx8 On-Chip RAM  
Datasheet  
Chapter 6 Functional Description  
6.1  
Microsequencer  
The COM20022I contains an internal microsequencer which performs all of the control operations  
necessary to carry out the ARCNET protocol. It consists of a clock generator, a 544 x 8 ROM, a program  
counter, two instruction registers, an instruction decoder, a no-op generator, jump logic, and  
reconfiguration logic.  
The COM20022I derives a 20 MHz and a 10 MHz clock from the output clock of the Clock Multiplier.  
These clocks provide the rate at which the instructions are executed within the COM20022I. The 20 MHz  
clock is the rate at which the program counter operates, while the 10 MHz clock is the rate at which the  
instructions are executed. The microprogram is stored in the ROM and the instructions are fetched and  
then placed into the instruction registers. One register holds the opcode, while the other holds the  
immediate data. Once the instruction is fetched, it is decoded by the internal instruction decoder, at which  
point the COM20022I proceeds to execute the instruction. When a no-op instruction is encountered, the  
microsequencer enters a timed loop and the program counter is temporarily stopped until the loop is  
complete. When a jump instruction is encountered, the program counter is loaded with the jump address  
from the ROM. The COM20022I contains an internal reconfiguration timer which interrupts the  
microsequencer if it has timed out. At this point the program counter is cleared and the MYRECON bit of  
the Diagnostic Status Register is set.  
Revision 09-27-07  