欢迎访问ic37.com |
会员登录 免费注册
发布采购

COM20020-5 参数 Datasheet PDF下载

COM20020-5图片预览
型号: COM20020-5
PDF下载: 下载PDF文件 查看货源
内容描述: 通用局域网控制器2K ×8板载RAM [Universal Local Area Network Controller with 2K x 8 On-Board RAM]
分类和应用: 控制器局域网
文件页数/大小: 58 页 / 248 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号COM20020-5的Datasheet PDF文件第30页浏览型号COM20020-5的Datasheet PDF文件第31页浏览型号COM20020-5的Datasheet PDF文件第32页浏览型号COM20020-5的Datasheet PDF文件第33页浏览型号COM20020-5的Datasheet PDF文件第35页浏览型号COM20020-5的Datasheet PDF文件第36页浏览型号COM20020-5的Datasheet PDF文件第37页浏览型号COM20020-5的Datasheet PDF文件第38页  
3. The third possibility which may occur after a  
FREE BUFFER ENQUIRY is issued is if the  
destination node does not respond at all. In this  
case, the TA bit is set to a logic "1", while the  
TMA bit remains at a logic "0". The user should  
determine whether the node should try to  
reissue the transmit command.  
alerted to the fact that the previous reception  
has concluded, it may issue the "Enable  
Receive to Page fnn" command, which resets  
the RI bit to logic "0" and selects a new page in  
the RAM buffer. Again, the appropriate buffer  
size is specified in the "Define Configuration"  
command.  
Typically, the page which just  
4. The fourth possibility is if a non-traditional  
response is received (some pattern other than  
ACK or NAK, such as noise). In this case, the  
token is not passed onto the next node, which  
causes the Lost Token Timer of the next node to  
received the data packet will be read by the  
microcontroller at this point.  
Once the "Enable Receive to Page fnn"  
command is issued, the microcontroller may  
attend to other duties. There is no way of  
knowing how long the new reception will take,  
since another node may transmit a packet at  
any time. When another node does transmit  
a packet to this node, and if the "Define  
Configuration" command has enabled the  
reception of long packets, the COM20020-5  
interprets the packet as either a long or short  
packet, depending on whether the content of the  
buffer location 2 is zero or non-zero. The format  
of the buffer is shown in Figure 7. Address 0  
contains the Source Identifier (SID), Address 1  
contains the Destination Identifier (DID), and  
Address 2 contains, for short packets, the value  
time out, thus generating  
reconfiguration.  
a
network  
The "Disable Transmitter" command may be  
used to cancel any pending transmit command  
when the COM20020-5 next receives the token.  
Normally, in an active network, this command  
will set the TA status bit to a logic "1" when the  
token is received. If the "Disable Transmitter"  
command does not cause the TA bit to be set in  
the time it takes the token to make a round trip  
through the network, one of three situations  
exists. Either the node is disconnected from the  
network, or there are no other nodes on the  
network, or the external receive circuitry has  
failed. These situations can be determined by  
either using the improved diagnostic features of  
the COM20020-5 or using another software  
timeout which is greater than the worst case  
time for a round trip token pass, which occurs  
when all nodes transmit a maximum length  
message.  
256-N, where N represents the  
number of  
information bytes (data bytes) in the message,  
or for long packets, the value 0, indicating that  
it is indeed a long packet. In the latter case,  
Address 3 contains the value 512-N, where N  
represents the number of information bytes  
(data bytes) in the message. Note that on  
reception, the COM20020-5 deposits packets  
into the RAM buffer in the same format that the  
transmitting node arranges them, which allows  
Receive Sequence  
for  
a message to be received and then  
A receive sequence begins with the RI status bit  
becoming a logic "1", which indicates that a  
retransmitted without rearranging any bytes in  
the RAM buffer other than the SID and DID.  
Once the packet is received and stored correctly  
previous reception has concluded.  
The  
in the selected buffer  
matches the packet,  
microcontroller will be interrupted if the  
corresponding bit in the Interrupt Mask Register  
and the checksum  
the COM20020-5 sets the  
is set to logic "1".  
microcontroller must periodically check the  
Status Register. Once the microcontroller is  
Otherwise, the  
RI bit to logic "1" to signal the microcontroller  
that the reception is complete.  
34  
 复制成功!