Register should be written before the Node ID  
Register. Once the Node ID Register is written  
to, the COM20020-5 reads the value and  
executes two write cycles to the RAM buffer.  
Address 0 is written with the data D1H and  
address 1 is written with the Node ID. The data  
pattern D1H was chosen arbitrarily, and is  
meant to provide assurance of proper  
microsequencer operation.  
another node on the network already has this  
ID, the COM20020-5 compares the value in the  
Node ID Register with the DID's of the token,  
and determines whether there is a response to  
it. Once the Diagnostic Status Register is read,  
the DUPID bit is cleared. The user may then  
attempt a new ID value, wait 840mS before  
checking the Duplicate ID bit, and repeat the  
process until a unique Node ID is found. At this  
point, the TX Enable bit may be set to allow the  
node to join the network. Once the node joins  
the network, a reconfiguration occurs, as usual,  
thus setting the MYRECON bit of the Diagnostic  
Status Register.  
INITIALIZATION SEQUENCE  
Bus Determination  
When the COM20020-5 is powered on the  
internal registers may be written to.  
Writing to  
The Tentative ID Register may be used to build  
a network map of all the nodes on the network,  
even once the COM20020-5 has joined the  
and reading from an odd address location from  
the COM20020-5's address space causes the  
COM20020-5 to determine the appropriate bus  
network.  
Once a value is placed in the  
Since writing a non-zero value to the  
Tentative ID Register, the COM20020-5 looks  
for a response to a token whose DID matches  
the Tentative ID Register. The software can  
record this information and continue placing  
Tentative ID values into the register to continue  
building the network map. A complete network  
map is only valid until nodes are added to or  
deleted from the network. Note that a node  
cannot detect the existence of the next logical  
node on the network when using the Tentative  
ID. To determine the next logical node, the  
software should read the Next ID Register.  
interface.  
Node ID Register wakes up the core, the Setup  
Register should be written to before the Node ID  
Register. Until a non-zero value is placed into  
the NID Register, no microcode is executed, no  
tokens are passed by this node, and no  
reconfigurations are generated by this node.  
Once a non-zero value is placed in the register,  
the core wakes up, but the node will not attempt  
to join the network until the TX Enable bit of the  
Configuration Register is set.  
Before setting the TX Enable bit, the software  
may make some determinations. The software  
may first observe the Receive Activity and the  
Token Seen bits of the Diagnostic Status  
Register to verify the health of the receiver and  
the network.  
IMPROVED DIAGNOSTICS  
The COM20020-5 allows the user to better  
manage the operation of the network through  
the use of the internal Diagnostic Status  
Register.  
Next, the uniqueness of the Node ID value  
placed in the Node ID Register is determined.  
The TX Enable bit should still be a logic "0" until  
it is ensured that the Node ID is unique. If this  
node ID already exists, the Duplicate ID bit of  
the Diagnostic Status Register is set after a  
maximum of 420mS (or 840mS if the ET1 and  
ET2 bits are other than 1,1). To determine if  
A
high level on the My Reconfiguration  
(MYRECON) bit indicates that the Token  
Reception Timer of this node expired, causing a  
reconfiguration by this node.  
Reconfiguration (RECON) bit of the Status  
Register interrupts the microcontroller, the  
interrupt service routine will typically read the  
After the  