Chaining mode.  
from Page fnn" command has just been issued.  
After the first Transmit status bits are cleared,  
the Status Register will again be updated with  
the results of the second transmission and a  
second interrupt resulting from the second  
In the Command Chaining Mode, at any time  
after the first command is issued, the processor  
can issue a second "Enable Transmit from Page  
fnn" command. The COM20020-5 stores the  
fact that the second transmit command was  
issued, along with the page number.  
transmission will occur.  
The COM20020-5  
guarantees minimum of 100ns interrupt  
a
inactive time interval before the following edge.  
After the first transmission is completed, the  
COM20020-5 updates the Status Register by  
setting the TTA bit, which generates an  
interrupt. The interrupt service routine should  
read the Status Register. At this point, the TTA  
bit will be found to be a logic "1" and the TMA  
(Transmit Message Acknowledge) bit will tell the  
processor whether the transmission was  
successful. After reading the Status Register,  
the "Clear Transmit Interrupt" command is  
issued, thus resetting the TTA bit and clearing  
The Transmitter Available (TA) bit of the  
Interrupt Mask Register now masks only the  
TTA bit of the Status Register, not the TA bit as  
in the non-chaining mode. Since the TTA bit is  
only set upon transmission of a packet (not by  
RESET), and since the TTA bit may easily be  
reset by issuing a "Clear Transmit Interrupt"  
command, there is no need to use the TA bit of  
the Interrupt Mask Register to mask interrupts  
generated by the TTA bit of the Status Register.  
the interrupt.  
Note that only the "Clear  
Transmit Interrupt" command will clear the TTA  
bit and the interrupt. It is not necessary,  
however, to clear the bit or the interrupt right  
away because the status of the transmit  
operation is double buffered in order to retain  
the results of the first transmission for analysis  
by the processor. This information will remain  
in the Status Register until the "Clear Transmit  
Interrupt" command is issued. Note that the  
interrupt will remain active until the command is  
issued, and the second interrupt will not occur  
until the first interrupt is acknowledged. The  
COM20020-5 guarantees a minimum of 100nS  
interrupt inactive time interval between  
interrupts. The TMA bit is also double buffered  
to reflect whether the appropriate transmission  
was a success. The TMA bit should only be  
considered valid after the corresponding TTA bit  
has been set to a logic "1". The TMA bit never  
causes an interrupt.  
In Command Chaining mode mode, the  
"Disable Transmitter" command will cancel the  
oldest transmission. This permits canceling a  
packet destined for a node not ready to receive.  
If both packets should be canceled, two  
"Disable Transmitter" commands should be  
issued.  
Receive Command Chaining  
Like the Transmit Command Chaining  
operation, the processor can issue two  
consecutive "Enable Receive from Page fnn"  
commands.  
After the first packet is received into the first  
specified page, the TRI bit of the Status  
Register will be set to logic "1", causing an  
interrupt. Again, the interrupt need not be  
serviced immediately. Typically, the interrupt  
service routine will read the Status Register. At  
this point, the RI bit will be found to be a logic  
"1". After reading the Status Register, the  
"Clear Receive Interrupt" command should be  
issued, thus resetting the TRI bit and clearing  
the interrupt. Note that only the "Clear Receive  
When the token is received again, the second  
transmission will be automatically initiated after  
the first is completed by using the stored  
"Enable Transmit from Page fnn" command.  
The operation is as if a new "Enable Transmit  
36  