C8051F50x-F51x  
Setting the EXTHOLD bit extends the minimum setup and hold times for the SDA line. The minimum SDA  
setup time defines the absolute minimum time that SDA is stable before SCL transitions from low-to-high.  
The minimum SDA hold time defines the absolute minimum time that the current SDA value remains stable  
after SCL transitions from high-to-low. EXTHOLD should be set so that the minimum setup and hold times  
meet the SMBus Specification requirements of 250 ns and 300 ns, respectively. Table 23.2 shows the min-  
imum setup and hold times for the two EXTHOLD settings. Setup and hold time extensions are typically  
necessary when SYSCLK is above 10 MHz.  
Table 23.2. Minimum SDA Setup and Hold Times  
EXTHOLD  
Minimum SDA Setup Time  
Minimum SDA Hold Time  
0
Tlow – 4 system clocks  
or  
1 system clock + s/w delay*  
11 system clocks  
3 system clocks  
1
12 system clocks  
*Note: Setup Time for ACK bit transmissions and the MSB of all data transfers. When using  
software acknowledgement, the s/w delay occurs between the time SMB0DAT or  
ACK is written and when SI is cleared. Note that if SI is cleared in the same write  
that defines the outgoing ACK value, s/w delay is zero.  
With the SMBTOE bit set, Timer 3 should be configured to overflow after 25 ms in order to detect SCL low  
timeouts (see Section “23.3.4. SCL Low Timeout” on page 228). The SMBus interface will force Timer 3 to  
reload while SCL is high, and allow Timer 3 to count when SCL is low. The Timer 3 interrupt service routine  
should be used to reset SMBus communication by disabling and re-enabling the SMBus.  
SMBus Free Timeout detection can be enabled by setting the SMBFTE bit. When this bit is set, the bus will  
be considered free if SDA and SCL remain high for more than 10 SMBus clock source periods (see  
Figure 23.4).  