C8051F50x-F51x  
23.1. Supporting Documents  
It is assumed the reader is familiar with or has access to the following supporting documents:  
1. The I2C-Bus and How to Use It (including specifications), Philips Semiconductor.  
2. The I2C-Bus Specification—Version 2.0, Philips Semiconductor.  
3. System Management Bus Specification—Version 1.1, SBS Implementers Forum.  
23.2. SMBus Configuration  
Figure 23.2 shows a typical SMBus configuration. The SMBus specification allows any recessive voltage  
between 3.0 V and 5.0 V; different devices on the bus may operate at different voltage levels. The bi-direc-  
tional SCL (serial clock) and SDA (serial data) lines must be connected to a positive power supply voltage  
through a pullup resistor or similar circuit. Every device connected to the bus must have an open-drain or  
open-collector output for both the SCL and SDA lines, so that both are pulled high (recessive state) when  
the bus is free. The maximum number of devices on the bus is limited only by the requirement that the rise  
and fall times on the bus not exceed 300 ns and 1000 ns, respectively.  
VIO = 5 V  
VIO = 3 V  
VIO = 5 V  
VIO = 3 V  
Master  
Device  
Slave  
Device 1  
Slave  
Device 2  
SDA  
SCL  
Figure 23.2. Typical SMBus Configuration  
23.3. SMBus Operation  
Two types of data transfers are possible: data transfers from a master transmitter to an addressed slave  
receiver (WRITE), and data transfers from an addressed slave transmitter to a master receiver (READ).  
The master device initiates both types of data transfers and provides the serial clock pulses on SCL. The  
SMBus interface may operate as a master or a slave, and multiple master devices on the same bus are  
supported. If two or more masters attempt to initiate a data transfer simultaneously, an arbitration scheme  
is employed with a single master always winning the arbitration. It is not necessary to specify one device  
as the Master in a system; any device who transmits a START and a slave address becomes the master  
for the duration of that transfer.  
A typical SMBus transaction consists of a START condition followed by an address byte (Bits7–1: 7-bit  
slave address; Bit0: R/W direction bit), one or more bytes of data, and a STOP condition. Bytes that are  
received (by a master or slave) are acknowledged (ACK) with a low SDA during a high SCL (see  
Figure 23.3). If the receiving device does not ACK, the transmitting device will read a NACK (not acknowl-  
edge), which is a high SDA during a high SCL.  
The direction bit (R/W) occupies the least-significant bit position of the address byte. The direction bit is set  
to logic 1 to indicate a "READ" operation and cleared to logic 0 to indicate a "WRITE" operation.  