欢迎访问ic37.com |
会员登录 免费注册
发布采购

S-8211CAX-I6T1G 参数 Datasheet PDF下载

S-8211CAX-I6T1G图片预览
型号: S-8211CAX-I6T1G
PDF下载: 下载PDF文件 查看货源
内容描述: 电池保护IC 1格包 [BATTERY PROTECTION IC FOR 1-CELL PACK]
分类和应用: 电池
文件页数/大小: 41 页 / 403 K
品牌: SII [ SEIKO INSTRUMENTS INC ]
 浏览型号S-8211CAX-I6T1G的Datasheet PDF文件第13页浏览型号S-8211CAX-I6T1G的Datasheet PDF文件第14页浏览型号S-8211CAX-I6T1G的Datasheet PDF文件第15页浏览型号S-8211CAX-I6T1G的Datasheet PDF文件第16页浏览型号S-8211CAX-I6T1G的Datasheet PDF文件第18页浏览型号S-8211CAX-I6T1G的Datasheet PDF文件第19页浏览型号S-8211CAX-I6T1G的Datasheet PDF文件第20页浏览型号S-8211CAX-I6T1G的Datasheet PDF文件第21页  
BATTERY PROTECTION IC FOR 1-CELL PACK  
S-8211C Series  
Rev.5.0_00  
(16) Discharge Overcurrent Detection Delay Time  
(Test Condition 10, Test Circuit 5)  
Discharge overcurrent detection delay time (tDIOV) is the time needed for VDO to go to “L” after the voltage V2  
momentarily increases (within 10 µs) from 0 V to 0.35 V under the set conditions of V1 = 3.5 V, V2 = 0 V.  
(17) Load Short-circuiting Detection Delay Time  
(Test Condition 10, Test Circuit 5)  
Load short-circuiting detection delay time (tSHORT) is the time needed for VDO to go to “L” after the voltage V2  
momentarily increases (within 10 µs) from 0 V to 1.6 V under the set conditions of V1 = 3.5 V, V2 = 0 V.  
(18) Charge Overcurrent Detection Delay Time  
(Test Condition 10, Test Circuit 5)  
Charge overcurrent detection delay time (tCIOV) is the time needed for VCO to go to “L” after the voltage V2  
momentarily decreases (within 10 µs) from 0 V to 0.3 V under the set conditions of V1 = 3.5 V, V2 = 0 V.  
(19) 0 V Battery Charge Starting Charger Voltage (Products with 0 V Battery Charging Function Is “Available”)  
(Test Condition 11, Test Circuit 2)  
The 0 V charge starting charger voltage (V0CHA) is defined as the voltage between the VDD pin and VM pin at which  
VCO goes to “H” (VVM +0.1 V or higher) when the voltage V2 is gradually decreased from the starting condition of  
V1 = V2 = 0 V.  
(20) 0 V Battery Charge Inhibition Battery Voltage (Products with 0 V Battery Charging Function Is  
“Unavailable”)  
(Test Condition 12, Test Circuit 2)  
The 0 V charge inhibition charger voltage (V0INH) is defined as the voltage between the VDD pin and VSS pin at which  
VCO goes to “H” (VVM +0.1 V or higher) when the voltage V1 is gradually increased from the starting conditions of  
V1 = 0 V, V2 = 4 V.  
Seiko Instruments Inc.  
17