 浏览型号S-80819CLNB-B6ET2G的Datasheet PDF文件第20页浏览型号S-80819CLNB-B6ET2G的Datasheet PDF文件第21页浏览型号S-80819CLNB-B6ET2G的Datasheet PDF文件第22页浏览型号S-80819CLNB-B6ET2G的Datasheet PDF文件第23页浏览型号S-80819CLNB-B6ET2G的Datasheet PDF文件第25页浏览型号S-80819CLNB-B6ET2G的Datasheet PDF文件第26页浏览型号S-80819CLNB-B6ET2G的Datasheet PDF文件第27页浏览型号S-80819CLNB-B6ET2G的Datasheet PDF文件第28页  
SUPER-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR  
S-808xxC Series  
Rev.4.3_00  
2-3. Temperature Characteristics of Hysteresis Voltage  
∆ + VDET ∆ − VDET  
The temperature characteristics for the hysteresis voltage is expressed as  
calculated as follows:  
and is  
Ta  
Ta  
∆ + VDET ∆ − VDET  
VHYS  
VDET  
∆ − VDET  
Ta  
=
×
Ta  
Ta  
„ Standard Circuit  
R*1  
100 kΩ  
VDD  
VSS  
OUT  
*1. R is unnecessary for CMOS output products.  
Figure 20  
Caution The above connection diagram and constants do not guarantee correct operation. Perform  
sufficient evaluation using the actual application to set the constants.  
„ Technical Terms  
1. Detection Voltage (VDET), Release Voltage (+VDET  
)
The detection voltage (VDET) is a voltage at which the output turns to low. The detection voltage varies slightly  
among products of the same specification. The variation of detection voltage between the specified minimum  
(VDET) Min. and the maximum (VDET) Max. is called the detection voltage range (Refer to Figure 21).  
Example: For the S-80815CN, the detection voltage lies in the range of 1.470(VDET)1.530.  
This means that some S-80815CNs have 1.470 V for VDET and some have 1.530 V.  
The release voltage (+VDET) is a voltage at which the output turns to high. The release voltage varies slightly  
among products of the same specification. The variation of release voltages between the specified  
minimum (+VDET) Min. and the maximum (+VDET) Max. is called the release voltage range (Refer to Figure  
22). The range is calculed from the actual detection voltage (VDET) of a product and is expressed by  
VDET×1.03≤+VDET≤−VDET ×1.08.  
Example: For the S-80815CN, the release voltage lies in the range of 1.514(+VDET)1.652.  
This means that some S-80815CNs have 1.514 V for +VDET and some have 1.652 V.  