STK672-120-SL-E
Package Dimensions
unit:mm (typ)
46.6
41.2
8.5
3.6
1
12
0.4
5.2
2.0
0.5
7.4
11 2=22
(9.6)
Figure 1 Derating Curve of Motor Current, I
vs. STK672-120-SL-E Operating Substrate Temperature, Tc
OH,
I
-- Tc
OH
4.5
V
=24V
CC
Operating region when f ≥200Hz
CL
Motor: R=0.4Ω
4.0
3.5
3.0
2.5
2.0
1.5
1.0
L=1.2mH
Operating region in hold mode
2.4
2.0
0.5
0
0
20
40
60
80
100 105
120
Operating substrate temperature, Tc -- °C
Notes
• The current range given above represents conditions when output voltage is not in the avalanche state.
• Tc must measure surface metal temperature on rear side center of this device.
No. A2140-3/11