PM4100APD
SA2102D
Name
J7
J8
J9
J10
State
A
A
A
A: Setting to A and J20 to + enables the FAST
output mode. Leaving J10 and J20 open disables
FAST mode and enables standard mode.
J11
J12
J13
B
B
A
SA4102A
Name
J7
J8
J9
J10
J11
J12
J13
J14, J15
State
A
A
A
A
B
B
A
sames
Set to B to enable stepper motor or counter
connectors (CON 4 and CON 5)
J14, J15 B. Connect if a stepper motor or counter is to be
connected.
J17,
J18,
J19
Rated conditions select (J17 for R0, J18 for R1,
J19 for R2). Please refer to the SA2102D
datasheet for further information. For Fast mode,
any combination except all to +. For different
normal mode settings, refer to the SA2102D
datasheet. Note: On module + = V
DD
and - = V
SS
J20
“+” : FAST mode enabled. “-” or OPEN: Standard
mode enabled. Also see J10.
J21
CLOSED: Inserting the jumper enables the pulse
stability circuitry. OPEN: Leaving it open disables
the pulse stability circuitry.
J23
J25
“-”
A
J17, J18, Rated conditions select (J17 for R0, J18 for R1,
J19, J21, J19 for R2, J21 for R3). Please refer to the
SA4102 datasheet for further information.
J20
Fms (see datasheet). Leave J20 open for fast
pulse output.
J23
Filter output select. Set to + for Averaging filter.
Set to - for Filtered instantaneous output.
J25
A
Bi-Directional Energy Measurement
J4
J5
A
B
Uni-Directional Energy Measurement
Forward
J3
A
B
J4
J5
Reverse
+
A
A
Bi-Directional Energy Measurement
J4
J5
Uni-Directional Energy Measurement
Forward
J3
J4
J5
Reverse
J3
J4
J5
-
A
A
+
A
A
J3
J4
J5
-
A
A
Table 8: Jumper options for SA4102A
Table 7: Jumper options for SA2102D
6/14