Datasheet
RGSX5TS65E
lFRD Electrical Characteristics (at Tj = 25°C unless otherwise specified)
Values
Typ.
Parameter
Symbol
Conditions
IF = 75A
Unit
V
Min.
Max.
VF
Tj = 25°C
Diode Forward Voltage
-
-
1.45
1.55
1.90
-
Tj = 175°C
Diode Reverse Recovery
Time
trr
-
-
-
-
-
-
-
-
116
9.2
-
-
-
-
-
-
-
-
ns
A
Diode Peak Reverse
Recovery Current
IF = 75A,
Irr
VCC = 400V,
diF/dt = 200A/μs,
Tj = 25°C
Diode Reverse Recovery
Charge
Qrr
Err
trr
0.61
20
μC
μJ
ns
A
Diode Reverse Recovery
Energy
Diode Reverse Recovery
Time
311
14
Diode Peak Reverse
Recovery Current
IF = 75A,
Irr
VCC = 400V,
diF/dt = 200A/μs,
Tj = 175°C
Diode Reverse Recovery
Charge
Qrr
Err
2.46
172
μC
μJ
Diode Reverse Recovery
Energy
www.rohm.com
© 2021 ROHM Co., Ltd. All rights reserved.
2021.01 - Rev.A
4/11