BM28723AMUV
Register Map - continued
Address Initial Value Recommended value
Description
Function
Threshold setting
0x30
0x31
0x32
0x33
0x34
0x36
0x37
0x38
0x39
0x3A
0x3B
0x3C
0x3D
0x3E
0x3F
0x40
0x41
0x42
0x51
0x53
0x40
0x80
0x3B
0x13
0x40
0x3B
0x13
0x40
0x80
0x3B
0x13
0x40
0x3B
0x13
0x00
0x40
0x3B
0x13
0x00
0x0C
0x40
0x80
0x3B
0x13
0x40
0x3B
0x13
0x40
0x80
0x3B
0x13
0x40
0x3B
0x13
0x00
0x40
0x3B
0x13
0x00
0x0C
AGC_TH1 setting of DRC2
Slope (α) setting of DRC2
RATE setting of DRC2
TIME setting of DRC2
AGC_TH2 setting of DRC2
RATE setting of DRC2
TIME setting of DRC2
AGC_TH1 setting of DRC3
Slope (α) setting of DRC3
RATE setting of DRC3
TIME setting of DRC3
AGC_TH2 setting of DRC3
RATE setting of DRC3
TIME setting of DRC3
DRC4 ON
Slope setting
A_RATE and R_RATE setting
A_TIME and R_TIME setting
Threshold setting
A_RATE and R_RATE setting
A_TIME and R_TIME setting
Threshold setting
Slope setting
A_RATE and R_RATE setting
A_TIME and R_TIME setting
Threshold setting
A_RATE and R_RATE setting
A_TIME and R_TIME setting
ON/OFF setting
AGC_TH2 setting of DRC4
RATE setting of DRC4
TIME setting of DRC4
Bi-quad type filter1
Threshold setting
A_RATE and R_RATE setting
A_TIME and R_TIME setting
Select of BQ soft transition Band
Setting of transition time and wait time
Bi-quad type filter2
Soft transition start, 0x0: Stop 0x1:
Start
0x58
0x59
0x60
Write Only
Read Only
0x00
-
Bi-quad type filter3
-
Bi-quad type filter4
Soft transition flag
Select of BQ independence or
synchronous setting
0x00
The coefficient is written directly. 1
0x61
0x62
0x63
0x64
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
The coefficient is written directly. 2 Coefficient address bit7 to bit0
The coefficient is written directly. 3 Coefficient data bit23 to bit16
The coefficient is written directly. 4 Coefficient data bit15 to bit8
The coefficient is written directly. 5 Coefficient data bit7 to bit0
The writing of coefficients is
The coefficient is written directly. 6
performed
0x65
Write Only
-
0x66
0x67
0x68
0x70
0x71
0x72
Read Only
Read Only
Read Only
0x00
-
The coefficient is written directly. 7 Coefficient reading bit23 to bit16
The coefficient is written directly. 8 Coefficient reading bit15 to bit8
The coefficient is written directly. 9 Coefficient reading bit7 to bit0
-
-
0x00
0x00
-
Small signal detection1
Small signal detection2
Small signal detection3
Small signal detection level setting
Small signal detection time setting
Small signal detection flag read-back
0x00
Read Only
Setting of the peak level hold time
interval
0x74
0x75
0x76
0x00
0x00
Level meter1
Level meter2
Level meter3
Write Only
Read Only
-
-
0x0: Lch 0x1: Rch 0x2: (Lch+Rch) /2
Level reading
(16bit high position 8bit)
Level reading
(16bit subordinate position 8bit)
0x77
0x78
Read Only
0x02
-
Level meter4
SDATAO
0x02
SDATAO select
www.rohm.com
TSZ02201-0C1C0E900720-1-2
31.Aug.2018 Rev.001
© 2018 ROHM Co., Ltd. All rights reserved.
66/79
TSZ22111 • 15 • 001