R8C/13 Group  
12.1 Timer (Timer X)  
Prescaler X Register  
b7  
Symbol  
PREX  
Address  
008C16  
After reset  
b0  
FF16  
Mode  
Function  
Setting range  
0016 to FF16  
RW  
RW  
Internal count source is counted  
Internal count source is counted  
Externally input pulses are counted  
Timer mode  
Pulse output mode  
Event counter mode  
0016 to FF16  
0016 to FF16  
RW  
RW  
Pulse width of externally input  
pulses is measured  
(Internal count source is counted)  
Pulse width  
measurement mode  
0016 to FF16  
0016 to FF16  
RW  
RW  
Pulse period of externally input  
pulses is measured  
Pulse period  
measurement mode  
(Internal count source is counted)  
Timer X Register  
b7  
b0  
Symbol  
TX  
Address  
008D16  
After reset  
FF16  
Function  
Underflow of Prescaler X is counted  
Setting range  
0016 to FF16  
RW  
RW  
Timer count source setting register  
b7 b6 b5 b4 b3 b2 b1 b0  
Symbol  
TCSS  
Address  
008E16  
After reset  
0016  
0
0
RW  
RW  
Bit symbol  
TXCK0  
Bit name  
Function  
b1 b0  
Timer X count source  
select bit(1)  
0 0 : f  
0 1 : f  
1
8
1 0 : f32  
TXCK1  
TYCK0  
RW  
RW  
RW  
RW  
RW  
RW  
1 1 : f  
2
b3 b2  
Timer Y count source  
select bit(1)  
0 0 : f  
0 1 : f  
1
8
1 0 : fRING  
1 1 : Selects input from CNTR  
TYCK1  
TZCK0  
1
pin  
b5 b4  
Timer Z count source  
select bit(1)  
0 0 : f  
0 1 : f  
1
8
1 0 : Selects Timer Y underflow  
1 1 : f  
TZCK1  
(b7-b6)  
2
Reserved bit  
Must be set to 0”  
NOTES:  
1. Avoid switching a count source, while a counter is in progress. Timer counter must be stopped before switching a count  
source.  
Figure 12.3 PREX Register, TX Register, and TCSS Register  