 浏览型号HD6417709SF133B的Datasheet PDF文件第132页浏览型号HD6417709SF133B的Datasheet PDF文件第133页浏览型号HD6417709SF133B的Datasheet PDF文件第134页浏览型号HD6417709SF133B的Datasheet PDF文件第135页浏览型号HD6417709SF133B的Datasheet PDF文件第137页浏览型号HD6417709SF133B的Datasheet PDF文件第138页浏览型号HD6417709SF133B的Datasheet PDF文件第139页浏览型号HD6417709SF133B的Datasheet PDF文件第140页  
4.3  
Register Descriptions  
There are four registers related to exception handling. These are peripheral module registers, and  
therefore reside in area P4. They can be accessed by specifying the address in privileged mode  
only.  
1. The exception event register (EXPEVT) resides at address H'FFFFFFD4, and contains a 12-bit  
exception code. The exception code set in EXPEVT is that for a reset or general exception  
event. The exception code is set automatically by hardware when an exception occurs.  
EXPEVT can also be modified by software.  
2. The interrupt event register (INTEVT) resides at address H'FFFFFFD8, and contains a 12-bit  
interrupt exception code or a code indicating the interrupt priority. Which is set when an  
interrupt occurs depends on the interrupt source (see tables 6.4 and 6.5). The exception code or  
interrupt priority code is set automatically by hardware when an exception occurs. INTEVT  
can also be modified by software.  
3. Interrupt event register 2 (INTEVT2) resides at address H'04000000, and contains a 12-bit  
exception code. The exception code set in INTEVT2 is that for an interrupt request. The  
exception code is set automatically by hardware when an exception occurs.  
4. The TRAPA exception register (TRA) resides at address H'FFFFFFD0, and contains 8-bit  
immediate data (imm) for the TRAPA instruction. TRA is set automatically by hardware when  
a TRAPA instruction is executed. TRA can also be modified by software.  
The bit configurations of the EXPEVT, INTEVT, INTEVT2, and TRA registers are shown in  
figure 4.3.  
EXPEVT, INTEVT, and INTEVT2 registers  
TRA register  
31  
0
11  
0
31  
0
9
2
0
0 Exception code  
0
imm  
00  
0:  
Reserved bits, always read as 0  
imm: 8-bit immediate data in TRAPA instruction  
Figure 4.3 Bit Configurations of EXPEVT, INTEVT, INTEVT2, and TRA Registers  
Rev. 5.00, 09/03, page 92 of 760  