 浏览型号HD6417750SBP200的Datasheet PDF文件第324页浏览型号HD6417750SBP200的Datasheet PDF文件第325页浏览型号HD6417750SBP200的Datasheet PDF文件第326页浏览型号HD6417750SBP200的Datasheet PDF文件第327页浏览型号HD6417750SBP200的Datasheet PDF文件第329页浏览型号HD6417750SBP200的Datasheet PDF文件第330页浏览型号HD6417750SBP200的Datasheet PDF文件第331页浏览型号HD6417750SBP200的Datasheet PDF文件第332页  
11.2.9  
Second Alarm Register (RSECAR)  
RSECAR is an 8-bit readable/writable register used as an alarm register for the RTC’s BCD-coded  
second value counter, RSECCNT. When the ENB bit is set to 1, the RSECAR value is compared  
with the RSECCNT value. Comparison between the counter and the alarm register is performed  
for those registers among RSECAR, RMINAR, RHRAR, RWKAR, RDAYAR, and RMONAR in  
which the ENB bit is set to 1, and the RCR1 alarm flag is set when the respective values all match.  
The setting range is decimal 00 to 59 + ENB bit. The RTC will not operate normally if any other  
value is set.  
The ENB bit in RSECAR is initialized to 0 by a power-on reset. The other fields in RSECAR are  
not initialized by a power-on or manual reset, or in standby mode.  
Bit:  
7
6
5
4
3
2
1
0
ENB  
0
10-second units  
1-second units  
Initial value:  
R/W:  
Undefined Undefined Undefined Undefined Undefined Undefined Undefined  
R/W R/W R/W R/W R/W R/W R/W  
R/W  
11.2.10 Minute Alarm Register (RMINAR)  
RMINAR is an 8-bit readable/writable register used as an alarm register for the RTC’s BCD-  
coded minute value counter, RMINCNT. When the ENB bit is set to 1, the RMINAR value is  
compared with the RMINCNT value. Comparison between the counter and the alarm register is  
performed for those registers among RSECAR, RMINAR, RHRAR, RWKAR, RDAYAR, and  
RMONAR in which the ENB bit is set to 1, and the RCR1 alarm flag is set when the respective  
values all match.  
The setting range is decimal 00 to 59 + ENB bit. The RTC will not operate normally if any other  
value is set.  
The ENB bit in RMINAR is initialized by a power-on reset. The other fields in RMINAR are not  
initialized by a power-on or manual reset, or in standby mode.  
Bit:  
7
6
5
4
3
2
1
0
ENB  
0
10-minute units  
1-minute units  
Initial value:  
R/W:  
Undefined Undefined Undefined Undefined Undefined Undefined Undefined  
R/W R/W R/W R/W R/W R/W R/W  
R/W  
Rev. 6.0, 07/02, page 276 of 986  