 浏览型号HD6417750SBP200的Datasheet PDF文件第322页浏览型号HD6417750SBP200的Datasheet PDF文件第323页浏览型号HD6417750SBP200的Datasheet PDF文件第324页浏览型号HD6417750SBP200的Datasheet PDF文件第325页浏览型号HD6417750SBP200的Datasheet PDF文件第327页浏览型号HD6417750SBP200的Datasheet PDF文件第328页浏览型号HD6417750SBP200的Datasheet PDF文件第329页浏览型号HD6417750SBP200的Datasheet PDF文件第330页  
11.2.6  
Day Counter (RDAYCNT)  
RDAYCNT is an 8-bit readable/writable register used as a counter for setting and counting the  
BCD-coded day value in the RTC. It counts on the carry generated once per day by the hour  
counter.  
The setting range is decimal 01 to 31. The RTC will not operate normally if any other value is set.  
Write processing should be performed after stopping the count with the START bit in RCR2, or  
by using the carry flag.  
RDAYCNT is not initialized by a power-on or manual reset, or in standby mode.  
The setting range for RDAYCNT depends on the month and whether the year is a leap year, so  
care is required when making the setting. Taking the year counter (RYRCNT) value as the year,  
leap year calculation is performed according to whether or not the value is divisible by 400, 100,  
and 4.  
Bits 7 and 6 are always read as 0. A write to these bits is invalid, but the write value should always  
be 0.  
Bit:  
7
0
6
0
5
4
3
2
1
0
10-day units  
Undefined Undefined Undefined Undefined Undefined Undefined  
R/W R/W R/W R/W R/W R/W  
1-day units  
Initial value:  
R/W:  
R
R
11.2.7  
Month Counter (RMONCNT)  
RMONCNT is an 8-bit readable/writable register used as a counter for setting and counting the  
BCD-coded month value in the RTC. It counts on the carry generated once per month by the day  
counter.  
The setting range is decimal 01 to 12. The RTC will not operate normally if any other value is set.  
Write processing should be performed after stopping the count with the START bit in RCR2, or  
by using the carry flag.  
RMONCNT is not initialized by a power-on or manual reset, or in standby mode.  
Bits 7 to 5 are always read as 0. A write to these bits is invalid, but the write value should always  
be 0.  
Rev. 6.0, 07/02, page 274 of 986  