PULSE OUTPUT PORT MODE
9.3 Setting of pulse output port mode
9.3 Setting of pulse output port mode
Figures 9.3.1 to 9.3.5 show an initial setting example for registers relevant to the pulse output port mode,
where an underflow of timer A0 is used as a pulse output trigger (in pulse mode 1). Note that when using
interrupts, set up to enable the interrupts. For details, refer to “CHAPTER 6. INTERRUPTS.”
Selecting pulse output mode and Selecting each function
b7
b0
Waveform output mode register (Address A616
)
0
0
1
0
0
1
Pulse mode 1
Pulse widh modulation timer select bits
See Table 9.2.2.
Waveform output control bit 0
Fix this bit to “0” in pulse mode 1.
Waveform output control bit 1
Pulse output disabled
➀ Pulse output pins are floating until the pulse output becomes enabled.
Continue to “Figure 9.3.2.”
Fig. 9.3.1 Initial setting example for registers relevant to pulse output port mode (in pulse mode 1) (1)
7906 Group User’s Manual Rev.2.0
9-14