 浏览型号HYB18H512321AFL20的Datasheet PDF文件第33页浏览型号HYB18H512321AFL20的Datasheet PDF文件第34页浏览型号HYB18H512321AFL20的Datasheet PDF文件第35页浏览型号HYB18H512321AFL20的Datasheet PDF文件第36页浏览型号HYB18H512321AFL20的Datasheet PDF文件第38页浏览型号HYB18H512321AFL20的Datasheet PDF文件第39页浏览型号HYB18H512321AFL20的Datasheet PDF文件第40页浏览型号HYB18H512321AFL20的Datasheet PDF文件第41页  
HYB18H512321AF  
512-Mbit GDDR3  
Functional Description  
4.3  
Extended Mode Register Set Command (EMRS)  
The Extended Mode Register is used to set the output  
driver impedance value, the termination impedance  
value, the Write Recovery time value for Write with  
Autoprecharge. It is used as well to enable/disable the  
DLL, to issue the Vendor ID and to enable/disable the  
Low Power mode. There is no default value for the  
Extended Mode Register. Therefore it must be written  
after power up to operate the GDDR3 Graphics RAM.  
The Extended Mode Register can be programmed by  
performing a normal Mode Register Set operation and  
setting the BA0 bit to HIGH. All other bits of the EMR  
register are reserved and should be set to LOW.  
CLK#  
CLK  
CKE  
CS#  
RAS#  
CAS#  
The Extended Mode Register must be loaded when all  
banks are idle and no burst are in progress. The  
controller must wait the specified time tMRD before  
initiating any subsequent operation (Figure 16).  
The timing of the EMRS command operation is  
equivalent to the timing of the MRS command  
operation.  
WE#  
A0-A11  
BA0  
COD  
1
0
COD: Code to be loaded into  
the register  
BA1, BA2  
Don't Care  
Figure 15 Extended Mode Register Set Command  
A7  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
BA2  
BA1  
BA0  
A11  
A10  
A9  
A8  
0
1
LP  
V
RFU  
WR  
DLL  
WR  
Rtt  
Data Z  
0
Self-  
Output Driver  
DLL  
Enable  
A11  
A6  
A1  
A0  
Refresh  
Impedance  
0
1
32ms  
8ms  
0
1
Enable  
0
0
Autocal  
0
1
Disable  
35  
40  
45  
1
1
0
1
A10 Vendor ID  
A7  
A5  
A4  
WR  
0
1
Off  
On  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
11  
4
A3  
A2  
Termination  
0
0
1
0
1
0
ODT disabled  
RFU  
5
6
ZQ / 4  
ZQ / 2  
7
1
1
2)  
8
(Default)  
9
10  
Figure 16 Extended Mode Register Bitmap  
1. These settings are for debugging purposes only.  
2. Default termination values at Power Up.  
option implemented in the device) or no action is taken by  
the device (if option not implemented).  
3. The ODT disable function disables all terminators on  
the device.  
5. WR (write recovery time for autoprecharge) in clock  
cycles is calculated by dividing  
up to the next integer (WR[cycles] =  
mode register must be programmed to this value.  
t
WR (in ns) and rounding  
4. If the user activates bits in the extended mode register in  
an optional field, either the optional field is activated (if  
t
WR[ns] / CK[ns]). The  
t
Data Sheet  
37  
Rev. 1.73, 2005-08  
05122004-B1L1-JEN8  