November 2006
rev 1.4
ASM5P23S04A
Operating Conditions for ASM5I23S04A Industrial Temperature Devices
Parameter
Description
Min
Max
Unit
VDD
TA
Supply Voltage
3.0
-40
3.6
85
30
15
7
V
Operating Temperature (Ambient Temperature)
Load Capacitance, below 100 MHz
Load Capacitance, from 100 MHz to 133 MHz
Input Capacitance6
°C
pF
pF
pF
CL
CL
CIN
Note:
6. Applies to both Ref Clock and FBK.
Electrical Characteristics for ASM5I23S04A Industrial Temperature Devices
Parameter
Description
Test Conditions
Min
Max
Unit
VIL
VIH
IIL
Input LOW Voltage
Input HIGH Voltage
Input LOW Current
Input HIGH Current
0.8
V
V
2.0
VIN = 0V
50.0
µA
µA
IIH
VIN = VDD
100.0
I
OL = 8mA (-1, -2)
VOL
Output LOW Voltage 7
Output HIGH Voltage 7
0.4
V
V
IOH = 12mA (-1H, -2H)
I
I
OL = -8mA (-1, -2)
VOH
2.4
OH = -12mA (-1H, -2H)
TBD
TBD
TBD
TBD
Unloaded outputs 100MHz REF, Select
inputs at VDD or GND
IDD
Supply Current
mA
Unloaded outputs, 66MHz REF (-1, -2)
Unloaded outputs, 33MHz REF (-1, -2)
Note:
7. Parameter is guaranteed by design and characterization. Not 100% tested in production.
3.3 ‘SpreadTrak’ Zero Delay Buffer
7 of 15
Notice: The information in this document is subject to change without notice.