BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS  
AUGUST 1999 — REVISED NOVEMBER 1999  
THERMAL INFORMATION  
PEAK OVERLOAD ON-STATE CURRENT  
vs  
CURRENT DURATION  
TI4LAA  
40  
35  
30  
TISP4xxxL3BJ WILL  
CARRY CURRENT  
25  
20  
100 A2s  
OF TESTS 1 THRU 5  
CLAUSE 6.6, UL 1950,  
FOR FULL TEST TIME  
40 A  
15  
7 A  
10  
9
8
7
6
5
4
3.5  
2.2 A  
WIRING  
3
SIMULATOR  
2.5  
2
0·01  
0·1  
1
10  
100  
1000  
t - Current Duration - s  
Figure 2. PEAK OVERLOAD ON-STATE CURRENT AGAINST DURATION  
APPLICATIONS INFORMATION  
UL 1950, CSA C22.2 No. 950 and EN 60950  
These electrical safety standards for IT (Information Technology) equipment at the customer premise use the  
IEC (International Electro-technical Commission) 60950 standard as the core document. The IEC 60950  
covers fundamental safety criteria such as creepage and isolation. The connection to a telecommunication  
network voltage (TNV) is covered in clause 6.  
Europe is harmonised by CENELEC (Comité Européen de Normalization Electro-technique) under EN 60950  
(included in the Low Voltage Directive, CE mark). US has UL (Underwriters Laboratories) 1950 and Canada  
CSA (Canadian Standards Authority) C22.2 No. 950. The US and Canadian standards include regional  
changes and additions to the IEC 60950. A major addition is the inclusion of clause 6.6, power cross  
withstand and annex NAC covering testing. Remarks made for UL 1950 will generally be true for CSA 22.2  
No. 950.  
UL 1950, clause 6.6 — power cross  
Figure 3 shows the criterion flow for UL 1950 power cross. (This is a modified version of UL1950, Figure  
18b — Overvoltage flowchart) There are many routes for achieving a pass result. For discussion, each  
criterion has been given a letter reference. Brief details of any electrical testing is given as a criterion note.  
Test pass criteria are given in the bottom table of Figure 3.  