TISP4070L3BJ 参数 Datasheet PDF下载

TISP4070L3BJ图片预览
型号: TISP4070L3BJ
PDF下载: 下载PDF文件 查看货源
内容描述: 双向晶闸管过电压保护 [BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS]
分类和应用: 光电二极管
文件页数/大小: 14 页 / 219 K
品牌: POINN [ POWER INNOVATIONS LTD ]
 浏览型号TISP4070L3BJ的Datasheet PDF文件第2页浏览型号TISP4070L3BJ的Datasheet PDF文件第3页浏览型号TISP4070L3BJ的Datasheet PDF文件第4页浏览型号TISP4070L3BJ的Datasheet PDF文件第5页浏览型号TISP4070L3BJ的Datasheet PDF文件第6页浏览型号TISP4070L3BJ的Datasheet PDF文件第7页浏览型号TISP4070L3BJ的Datasheet PDF文件第8页浏览型号TISP4070L3BJ的Datasheet PDF文件第9页  
TISP4070L3BJ, TISP4350L3BJ
BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
Copyright © 1999, Power Innovations Limited, UK
AUGUST 1999 — REVISED NOVEMBER 1999
FCC PART 68 AND UL 1950 OVERVOLTAGE PROTECTORS
q
MODEM Protection against:
— FCC Part 68 Type A & B surge
— UL 1950, Clause 6. power cross
— CSA 22.2 No. 950, Clause 6. power cross
Ring-Tip Protection ...............TISP4350L3BJ
Electronics Protection ..........TISP4070L3BJ
Ion-Implanted Breakdown Region
Precise and Stable Voltage
Low Voltage Overshoot under Surge
DEVICE
‘4070
‘4350
V
DRM
V
58
275
V
(BO)
V
70
350
SMBJ PACKAGE
(TOP VIEW)
q
q
q
R(B)
1
2
T(A)
MDXXBG
device symbol
T
SD4XAA
q
Rated for UL 1950 and Part 68 Wave Shapes
SURGE
TYPE
A
B
STANDARD
FCC Part 68
FCC Part 68
UL 1950 / ITU-T K21
WAVE
SHAPE
10/160 µs
10/560 µs
9/720 µs
10/700 µs
I
TSP
A
50
30
40
R
Terminals T and R correspond to the
alternative line designators of A and B
description
These devices are designed to limit overvoltages on the telephone line. Overvoltages are normally caused by
a.c. power system or lightning flash disturbances which are induced or conducted on to the telephone line. A
single device provides 2-point protection and is typically used for the protection of 2-wire telecommunication
equipment (e.g. between the Ring and Tip wires for telephones and modems). Combinations of devices can
be used for multi-point protection (e.g. 3-point protection between Ring, Tip and Ground).
The protector consists of a symmetrical voltage-triggered bidirectional thyristor. Overvoltages are initially
clipped by breakdown clamping until the voltage rises to the breakover level, which causes the device to
crowbar into a low-voltage on state. This low-voltage on state causes the current resulting from the
overvoltage to be safely diverted through the device. The high crowbar holding current prevents d.c. latchup
as the diverted current subsides.These protectors are guaranteed to voltage limit and withstand the listed
lightning surges in both polarities.
After a Type A surge the equipment can be faulty, provided that the fault mode causes the equipment to be
unusable. The high current Type A surges (10/160, 200 A and 10/560, 100 A), will cause the TISP4xxxL3BJ
to fail short circuit, giving a non-operational equipment pass to Type A surges.
After a Type B surge the equipment must be operational. As the TISP4xxxL3BJ has a current rating of 40 A,
will survive both Type B surges, metallic (differential mode 25 A, 9/720) and longitudinal (common mode
37.5 A, 9/720), giving an operational pass to Type B surges.
For metallic protection, the TISP4350L3BJ is connected between the Ring and Tip conductors. For
longitudinal protection two TISP4350L3BJ protectors are used; one between the Ring conductor to ground
and the other between the Tip conductor to ground. The B type ringer has voltages of 56.5 V d.c. and up to
PRODUCT
INFORMATION
1
Information is current as of publication date. Products conform to specifications in accordance
with the terms of Power Innovations standard warranty. Production processing does not
necessarily include testing of all parameters.