PM7385 FREEDM-84A672
DATA SHEET
PMC-1990114
ISSUE 6
84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER
WITH ANY-PHY PACKET INTERFACE
RWB:
The indirect access control bit (RWB) selects between a configure (write) or
interrogate (read) access to the transmit channel provision RAM. The
address to the transmit channel provision RAM is constructed by
concatenating the TSLOT[6:0] and LINK[4:0] bits. Writing a logic zero to
RWB triggers an indirect write operation. Data to be written is taken from the
PROV and the CHAN[9:0] bits of the Indirect Data register. Writing a logic
one to RWB triggers an indirect read operation. Addressing of the RAM is the
same as in an indirect write operation. The data read can be found in the
PROV and the CHAN[9:0] bits of the Indirect Channel Data register.
BUSY:
The indirect access status bit (BUSY) reports the progress of an indirect
access. BUSY is set high when this register is written to trigger an indirect
access, and will stay high until the access is complete. At which point, BUSY
will be set low. This register should be polled to determine when data from an
indirect read operation is available in the TCAS Indirect Channel Data register
or to determine when a new indirect write operation may commence.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
141