RELEASED
PM7380 FREEDM-32P672
DATA SHEET
PMC-1990262
ISSUE 5
FRAME ENGINE AND DATA LINK MANAGER 32P672
Table 30 – Instruction Register
Length - 3 bits
Instructions Selected Register
Instruction Code IR[2:0]
EXTEST
IDCODE
SAMPLE
BYPASS
BYPASS
STCTEST
BYPASS
BYPASS
Boundary Scan
Identification
Boundary Scan
Bypass
Bypass
Boundary Scan
Bypass
000
001
010
011
100
101
110
111
Bypass
12.2.1 Identification Register
Length - 32 bits
Version number - 2H
Part Number - 7380H
Manufacturer's identification code - 0CDH
Device identification - 273800CDH
12.2.2 Boundary Scan Register
The boundary scan register is made up of 365 boundary scan cells, divided into
input observation (in_cell), output (out_cell), and bi-directional (io_cell) cells.
These cells are detailed in the following pages. The first 32 cells form the ID
code register, and carry the code 273800CDH. The cells are arranged as
follows:
Table 31 – Boundary Scan Chain
Pin/ Enable
Register Bit
Cell Type
Device I.D.
RBCLK_OEN
RBCLK
0
1
OUT_CELL
OUT_CELL
-
-
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA,INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
265