欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7380-PI 参数 Datasheet PDF下载

PM7380-PI图片预览
型号: PM7380-PI
PDF下载: 下载PDF文件 查看货源
内容描述: 帧引擎和数据链路管理32P672 [FRAME ENGINE AND DATA LINK MANAGER 32P672]
分类和应用:
文件页数/大小: 332 页 / 2479 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7380-PI的Datasheet PDF文件第122页浏览型号PM7380-PI的Datasheet PDF文件第123页浏览型号PM7380-PI的Datasheet PDF文件第124页浏览型号PM7380-PI的Datasheet PDF文件第125页浏览型号PM7380-PI的Datasheet PDF文件第127页浏览型号PM7380-PI的Datasheet PDF文件第128页浏览型号PM7380-PI的Datasheet PDF文件第129页浏览型号PM7380-PI的Datasheet PDF文件第130页  
RELEASED  
PM7380 FREEDM-32P672  
DATA SHEET  
PMC-1990262  
ISSUE 5  
FRAME ENGINE AND DATA LINK MANAGER 32P672  
high, receipt of a packet that is shorter than 32 bits (CRC-CCITT, Unspecified  
CRC or no CRC) or 48 bits (CRC-32) will cause the PMON Configurable  
Accumulator #1 register to increment. Small packet errors are ignored when  
RSPE1EN is set low.  
RFCSE1EN:  
The receive frame check sequence error accumulate enable bit (RFCSE1EN)  
enables counting of receive FCS error events. When RFCSE1EN is set high,  
a mismatch between the received FCS code and the computed CRC residue  
will cause the PMON Configurable Accumulator #1 register to increment.  
Receive frame check sequence errors are ignored when RFCSE1EN is set  
low.  
RABRT1EN:  
The receive abort accumulate enable bit (RABRT1EN) enables counting of  
receive HDLC abort events. When RABRT1EN is set high, receipt of an  
abort code (at least 7 contiguous 1's) will cause the PMON Configurable  
Accumulator #1 register to increment. Receive aborts are ignored when  
RABRT1EN is set low.  
RLENE1EN:  
The receive packet length error accumulate enable bit (RLENE1EN) enables  
counting of receive packet length error events. When RLENE1EN is set high,  
receipt of a packet that is longer than the programmable maximum or of a  
packet that in not octet aligned will cause the PMON Configurable  
Accumulator #1 register to increment. (Receipt of a packet that is both too  
long and not octet aligned results in only one increment.) Receive packet  
length errors are ignored when RLENE1EN is set low.  
RP1EN:  
The receive packet enable bit (RP1EN) enables counting of receive error-free  
packets. When RP1EN is set high, receipt of an error-free packet will cause  
the PMON Configurable Accumulator #1 register to increment. Receive error-  
free packets are ignored when RP1EN is set low.  
TABRT1EN:  
The transmit abort accumulate enable bit (TABRT1EN) enables counting of  
transmit HDLC abort events. When TABRT1EN is set high, insertion of an  
abort in the outgoing stream will cause the PMON Configurable Accumulator  
#1 register to increment. Transmit aborts are ignored when TABRT1EN is set  
low.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA,INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
115  
 复制成功!