RELEASED  
PM7351 S/UNI-VORTEX  
DATA SHEET  
PMC-1980582  
ISSUE 5  
OCTAL SERIAL LINK MULTIPLEXER  
Test-Logic-Reset  
The test logic reset state is used to disable the TAP logic when the device is in  
normal mode operation. The state is entered asynchronously by asserting input,  
TRSTB. The state is entered synchronously regardless of the current TAP  
controller state by forcing input, TMS high for 5 TCK clock cycles. While in this  
state, the instruction register is set to the IDCODE instruction.  
Run-Test-Idle  
The run test/idle state is used to execute tests.  
Capture-DR  
The capture data register state is used to load parallel data into the test data  
registers selected by the current instruction. If the selected register does not  
allow parallel loads or no loading is required by the current instruction, the test  
register maintains its value. Loading occurs on the rising edge of TCK.  
Shift-DR  
The shift data register state is used to shift the selected test data registers by  
one stage. Shifting is from MSB to LSB and occurs on the rising edge of TCK.  
Update-DR  
The update data register state is used to load a test register's parallel output  
latch. In general, the output latches are used to control the device. For  
example, for the EXTEST instruction, the boundary scan test register's parallel  
output latches are used to control the device's outputs. The parallel output  
latches are updated on the falling edge of TCK.  
Capture-IR  
The capture instruction register state is used to load the instruction register with  
a fixed instruction. The load occurs on the rising edge of TCK.  
Shift-IR  
The shift instruction register state is used to shift both the instruction register and  
the selected test data registers by one stage. Shifting is from MSB to LSB and  
occurs on the rising edge of TCK.  